Authorized distributor · Karachi

Home/Products/Scitek Global/Benchtop pH Meter

Scitek Global Weighing & measurement

Benchtop pH Meter

Models
PH-B25C; PH-B3C; PH-B3B; PH-B210; PH300F; PH400F; PH500T; PH-B920; PH-B100I; PH100B; PHI-B930; PH-B100T; PH-B120; PHI-B130; ION-B131
pH Range
0.00~14.00pH
pH Accuracy
±0.05pH
Resolution
0.01pH
Calibration Points
2 points

This is a economical benchtop pH/mV meter with color LCD, capacitive touch keys and many other advanced features at a low price and good quality.

Scitek Global 15 models

Product Description

Benchtop pH Meter specification for every model we supply. Figures are the manufacturer’s published values.

Benchtop pH Meter specification, by model, as published by Scitek Global
SpecificationValue
PH-B25C — Benchtop pH Meter, 2 Calibration Points
pH Range0.00~14.00pH
pH Accuracy±0.05pH
Resolution0.01pH
Calibration Points2 points
Calibration SolutionsUSA (pH4.01/7.00/10.01)
Temperature Compensation0~100°C, Manual
mV Range-1999~1999mV
mV Accuracy±10mV
Resolution1mV
Temperature Rage/
Temperature Accuracy/
Resolution/
Hold Function/
ConnectorBNC
DisplayLCD
Power RequirementsDC9V/400mA power adapter
Sizes (W×D×H)(mm)210×205×65
Shipping Size (W×D×H)(mm)320x260x200
N.W./G.W. (kg)1.5/2
PH-B3C — Benchtop pH Meter, 2 Calibration Points
pH Range0.00~14.00pH
pH Accuracy±0.01pH
Resolution0.01pH
Calibration Points2 points
Calibration SolutionsUSA (pH4.01/7.00/10.01)
Temperature Compensation0~100°C, Manual
mV Range-1999~1999mV
mV Accuracy±1mV
Resolution1mV
Temperature Rage/
Temperature Accuracy/
Resolution/
Hold Function/
ConnectorBNC
DisplayLCD
Power RequirementsDC9V/400mA power adapter
Sizes (W×D×H)(mm)210×205×65
Shipping Size (W×D×H)(mm)320x260x200
N.W./G.W. (kg)1.5/2
PH-B3B — Benchtop pH Meter, 2 Calibration Points
pH Range0.00~14.00pH
pH Accuracy±0.01pH
Resolution0.01pH
Calibration Points2 points
Calibration SolutionsUSA (pH4.01/7.00/10.01)
Temperature Compensation0~100°C, Manual or Automatic
mV Range-1999~1999mV
mV Accuracy±1mV
Resolution1mV
Temperature Rage0~100°C
Temperature Accuracy±1°C
Resolution1℃
Hold Function/
ConnectorBNC
DisplayLCD
Power RequirementsDC9V/400mA power adapter
Sizes (W×D×H)(mm)210×205×65
Shipping Size (W×D×H)(mm)320x260x200
N.W./G.W. (kg)1.5/2
PH-B210 — Benchtop pH Meter, 3 Calibration Points
pH — Range-1.00-15.00pH
pH — Resolution0.01pH
pH — Accuracy±0.01pH
pH — Calibration Points1 to 3 points
pH — pH Buffer OptionsUSA(4.01/7.00/10.01), NIST(4.01/6.86/9.18)
ORP — mV Range±1999mV
ORP — Relative mV Range/
ORP — Resolution1mV
ORP — Accuracy±1mV
ORP — Calibration Points/
Temperature — Range0~105°C/32~221°F
Temperature — Resolution0.1°C/0.1°F
Temperature — Accuracy±1°C/±1.8°F
Temperature — Offset Calibration1 point, reading ±10°C
Other Specifications — Temperature Compensation0-100°C, manual or automatic
Other Specifications — Stability Criteria/
Other Specifications — Calibration Due Alarm/
Other Specifications — Slope/Offset Display/
Other Specifications — Hold FunctionManual or auto-endpoint
Other Specifications — Memory/
Other Specifications — Communication Interface/
Other Specifications — ConnectorBNC, 3.5mm jack socket
Other Specifications — DisplayCustom LCD(120×60mm)
Other Specifications — Power RequirementsDC9V power adapter
Other Specifications — Sizes(W×D×H)(mm)210x205x75
Other Specifications — Shipping Size (W×D×H)(mm)320x260x200
Other Specifications — N.W./G.W. (kg)1.5/2
PH300F — Benchtop pH Meter, 5 Calibration Point PH300F
ParameterspH/Temp.(mV)
pH — Range-2.00 to 20.00pH
pH — Resolution0.1, 0.01 pH
pH — Accuracy±0.01 pH
pH — Calibration PointsUp to 5
pH — Standard CustomizationYes
pH — Standard RecognitionNIST, GB and DIN buffers
mV — Range-2000.0 to 2000.0 mV
mV — Resolution0.1 mV
mV — Accuracy±0.3 mV or ±0.1%
Temperature — Range-5 to 110 ºC, 23 to 230 ºF
Temperature — UnitºC, ºF
Temperature — Resolution0.1
Temperature — Accuracy±0.2
Measurement — Reading ModeAuto Read (Fast, Medium, Slow), Timed, Continuous
Measurement — Reading PromptsReading, Stable, Locked
Measurement — Temp. CompensationATC, MTC
Data Management — Data Storage500 results each
Data Management — GLP FeaturesYes
Inputs — pH ElectrodeBNC(Q9)
Inputs — Temp. Probe4-pin aviation connector
Outputs — USBPC
Outputs — RS 232Printer
Display Options — BacklightYes
Display Options — Auto Shutdown1~60 min, off
Display Options — IP RatingIP54
Display Options — Date and TimeYes
General — PowerAC Adapter, 100-240V AC input, DC9V output
General — External Size (W×D×H)242×195×68
General — Shipping Size (W×D×H)(mm)370×320×220
PH400F — Benchtop pH Meter, 5 Calibration Points
ParameterspH/Temp.(mV)
pH — Range-2.000 to 20.000 pH
pH — Resolution0.1, 0.01, 0.001pH
pH — Accuracy±0.002 pH
pH — Calibration PointsUp to 5
pH — Standard CustomizationYes
pH — Standard RecognitionNIST, GB, DIN, USA and MERK buffers
mV — Range-2000.00 to 2000.00 mV
mV — Resolution0.1, 0.01 mV
mV — Accuracy±0.1 mV or ±0.03%
Temperature — Range-10 to 135 ºC, 14 to 275 ºF
Temperature — UnitºC, ºF
Temperature — Resolution0.1
Temperature — Accuracy±0.1
Measurement — Reading ModeAuto Read (Fast, Medium, Slow), Timed, Continuous
Measurement — Reading PromptsReading, Stable, Locked
Measurement — Temp. CompensationATC, MTC
Data management — Data Storage500 results each
Data management — GLP FeaturesYes
Inputs — pH ElectrodeBNC(Q9)
Inputs — Temp. Probe4-pin aviation connector
Outputs — USBUSB 2.0 flash memory device, PC
Outputs — RS 232Printer
Display Options — BacklightYes
Display Options — Auto Shutdown1~60 min, off
Display Options — IP RatingIP54
Display Options — Date and TimeYes
General — ElectricityAC Adapter, 100-240V AC input, DC9V output
General — Sizes(W×D×H)242×195×68
General — Shipping Size (W×D×H)(mm)370×305×330
PH500T — Benchtop pH Meter PH500T
ParameterspH/Temp.(mV/ORP)
pH — Range-2.000 to 20.000 pH
pH — Resolution0.1, 0.01, 0.001pH
pH — Accuracy±0.002 pH
pH — Calibration PointsUp to 6
pH — Standard CustomizationYes
pH — Calibration ReminderYes
pH — Standard RecognitionNIST, GB, DIN, USA, MERK, JIS buffers
pH — Slope LimitYes
mV/ORP — Range-2000.00 to 2000.00 mV
mV/ORP — Resolution0.1, 0.01 mV
mV/ORP — Accuracy±0.1 mV or ±0.03%
mV/ORP — EH ORP ModeYes
mV/ORP — ORP Calibration Points1 custom point (relative mV)
Temperature — Range-10 to 135 ºC, 14 to 275 ºF
Temperature — UnitºC, ºF
Temperature — Resolution0.1
Temperature — Accuracy±0.1
Measurement — Reading ModeAuto Read (Fast, Medium, Slow), Timed, Continuous
Measurement — Reading PromptsReading, Stable, Locked
Measurement — Temp. CompensationATC, MTC
Data management — Data Storage1000 Groups
Data management — GLP FeaturesYes
Data management — Log ManagementYes
Inputs — pH ElectrodeBNC(Q9)
Inputs — Temp. Probe4-pin aviation connector
Outputs — USBUSB 2.0 flash memory device, PC, Scanner
Outputs — RS 232Printer, auto-sampler
Display options — BacklightYes
Display options — Auto Shutdown1~60 min, off
PH-B920 — Benchtop pH Meter, 5 Points Calibration
pH — Range-2.000~20.000pH
pH — Resolution0.001, 0.01, 0.1pH, selectable
pH — Accuracy±0.002pH
pH — Calibration Points1 to 5 points
pH — pH Buffer OptionsUSA, NIST, DIN, 2 custom buffers
ORP — mV Range±1999mV
ORP — Relative mV Range±1999mV
ORP — Resolution0.1, 1mV, selectable
ORP — Accuracy±0.2mV
ORP — Calibration Points1 point
Temperature — Range0~105°C/32~221°F
Temperature — Resolution0.1°C/0.1°F
Temperature — Accuracy±0.5°C/±0.9°F
Temperature — Offset Calibration1 point, reading ±10°C
Other Specifications — Temperature Compensation0-~100°C, manual or automatic
Other Specifications — Stability CriteriaLow or high
Other Specifications — Calibration Due Alarm1 to 31 days or off
Other Specifications — Slope/Offset DisplayYes
Other Specifications — Hold FunctionManual or auto-endpoint
Other Specifications — Memory500 data sets
Other Specifications — Communication InterfaceUSB
Other Specifications — ConnectorBNC, 3.5mm jack socket
Other Specifications — DisplayCustom LCD(125×100mm)
Other Specifications — Power RequirementsDC5V power adapter
Other Specifications — Sizes(W×D×H)(mm)210×188×60
Other Specifications — Shipping Size (W×D×H)(mm)350x250x200
Other Specifications — N.W./G.W. (kg)1.5/2
PH-B100I — Benchtop pH Meter, Automatic Calibration
pH — Range(-2.00-20.00) pH
pH — Resolution0.01/0.1 pH
pH — Accuracy±0.01 pH ±1digit
pH — Auto. Temperature Compensation-9.9℃~130℃(14.1~266)℉
mV (ORP Probe Optional) — Range-1, 999mV -+1, 999mV
mV (ORP Probe Optional) — Resolution± 0.1/1mV
mV (ORP Probe Optional) — Accuracy±0.1% FS ±1digit
Temperature — Range-9.9℃~130℃(14.1~266)℉
Temperature — Resolution/ Accuracy0.1℃; ±0.5℃±1digit
Data Storage450 groups
Data Output1. USB to Flash Disk
Data Output2. Wireless connection to printer (the printer is optional)
Power SupplyDC12V
Packing Including1. PH-B100I Meter× 1
Packing Including2. Plastic pH electrode 201T× 1
Packing Including3. pH buffer solution: 4.00/7.00/10.01 50mL, one for each
Packing Including4. Electrode holder × 1
Packing Including5. Power adaptor × 1
Shipping Size (WxDxH)(mm)510x330x140
N.W. / G.W. (kg)1.7 / 3
PH100B — Benchtop pH Meter, 2 Calibration Point
ParameterspH/mV
pH — Range0.00 to 14.00 pH
pH — Resolution0.01pH
pH — Accuracy±0.01 pH
pH — Calibration PointsUp to 2
pH — Standard RecognitionNIST buffers
mV — Range-1800 to 1800 mV
mV — Resolution1 mV
mV — Accuracy±0.1%FS
Measurement — Reading ModeContinuous
Measurement — Temp. CompensationMTC
Inputs — pH ElectrodeBNC(Q9)
Display Options — BacklightYes
Display Options — Auto Shutdown300, 600, 1200, 1800, 3600 sec., off
Display Options — IP RatingIP54
General — ElectricityAC Adapter, 100-240V AC input, DC9V output
General — External Size (W×D×H)(mm)200×160×63
General — Shipping Size (W×D×H)(mm)300×290×140
General — G.W. (kg)1.5
Includes — AccessoriesE-201F pH composite electrode NIST pH standard solution (4.01, 7.00, 10.01), 50ml/vial Electrode stand
PHI-B930 — Benchtop pH/Ion Meter, 5 Calibration Points
Range-2.000~20.000pH
Resolution0.001, 0.01, 0.1pH, selectable
Accuracy±0.002pH
Calibration Points1 to 5 points
pH Buffer OptionsUSA, NIST, DIN, 2 custom buffers
Range0.001~19999 (depending on the range of ISE)
Resolution0.001, 0.01, 0.1, 1
Accuracy±0.5% F.S. (monovalent), ±1% F.S. (divalent)
Measurement Unitsppm, mg/L, mol/L, mmol/L
Calibration Points2 to 5 points
Calibration Solutions0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000
mV Range±1999.9mV
Relative mV Range±1999.9mV
Resolution0.1, 1mV, selectable
Accuracy±0.2mV
Calibration Points1 point
Range0~105°C/32~221°F
Resolution0.1°C/0.1°F
Accuracy±0.5°C/±0.9°F
Offset Calibration1 point, reading ±10°C
Temperature Compensation0~100°C, manual or automatic
Stability CriteriaLow or high
Calibration Due Alarm1 to 31 days or off
Slope/Offset DisplayYes
Hold FunctionManual or auto-endpoint
Memory500 data sets
Communication InterfaceUSB
ConnectorBNC, 3.5mm jack socket
DisplayCustom LCD(125x100mm)
Power RequirementsDC5V power adapter
PH-B100T — Benchtop pH Meter, Touch Screen
pH — Range(-2.000-20.000) pH
pH — Resolution0.001/0.01 pH
pH — Accuracy±0.002pH ±1digit
pH — Auto. Temperature Compensation-10.0~135℃ (14.0~275.0)℉
mV (ORP Probe Optional) — Range-1, 999mV -+1, 999mV
mV (ORP Probe Optional) — Resolution± 0.1/1mV
mV (ORP Probe Optional) — Accuracy±0.03% FS ±1digit
Temperature — Range-10.0~135℃(14.0~275.0)℉
Temperature — Resolution/ Accuracy0.1℃; ±0.2℃
Data Storage5000 groups
Data Output1. USB to Flash Disk
Data Output2. USB to PC
Data Output3. Wireless connection to printer (the printer is optional)
Power SupplyDC12V
Packing Including1. PH-B100T Meter
Packing Including2. 201G Refillable glass pH probe: 1pc
Packing Including3. Temp-01 Stainless steel probe: 1pc
Packing Including4. pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each
Packing Including5. F01 Flexible probe holder: 1pc
Packing Including6. Magnetic stirrer: 1pc
Packing Including7. PC cable: 1pc
Packing Including8. A01 Power adaptor
Shipping Size (WxDxH)(mm)430x600x130
N.W. / G.W. (kg)2.3 / 3
PH-B120 — Benchtop pH Meter, 5 Calibration Point
pH — Range-2.000-20.000 pH
pH — Resolution0.001,0.01, selectable
pH — Accuracy±0.002pH
pH — Calibration Points1 to 5 points
pH — Ph Buffer OptionsUSA, NIST, DIN, 5 custom buffers
ORP — mV Range±2000.0mV
ORP — Relative mV Range±2000.0mV
ORP — Resolution0.1mV
ORP — Accuracy±0.2mV
ORP — Calibration Points1 point
Ion — Range_
Ion — Resolution_
Ion — Accuracy_
Ion — Measurement_
Ion — Units_
Ion — Calibration Points_
Ion — Measurement Methods_
Ion — Electrode Management_
Water Hardness — Range_
Water Hardness — Resolution_
Water Hardness — Accuracy_
Water Hardness — Calibration Points_
Temperature — Range0~105°C / 32~221°F
Temperature — Resolution0.1°C/0.1°F
Temperature — Accuracy±05°C/0.9°F
Temperature — Offset Calibration1 point, reading ±10°C
Other Specifications — Temperature Compensation0~100°C, manual or automatic
Other Specifications — Solution Temperature Coefficient25°C
Other Specifications — Stability CriteriaStandard or high-accuracy
Other Specifications — Calibration Due Alarm1to 31 days or off
PHI-B130 — Benchtop pH Meter, 5 Calibration Point
pH — Range-2.000-20.000 pH
pH — Resolution0.001,0.01, selectable
pH — Accuracy±0.002pH
pH — Calibration Points1 to 5 points
pH — Ph Buffer OptionsUSA, NIST, DIN, 5 custom buffers
ORP — mV Range±2000.0mV
ORP — Relative mV Range±2000.0mV
ORP — Resolution0.1mV
ORP — Accuracy±0.2mV
ORP — Calibration Points1 point
Ion — Range0.001~30000 (depending on the range of ISE)
Ion — Resolution0.001, 0.01, 0.1, 1
Ion — Accuracy±0.5% F.S. (monovalent), ±1% F.S. (divalent))
Ion — Measurementppm, mg/L, mol/L, mmol/L
Ion — Unitsppm, mg/L, mol/L, mmol/L
Ion — Calibration Points2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000)
Ion — Measurement MethodsDirect reading, known addition, known subtraction, sample addition, sample subtraction
Ion — Electrode Management1 to 3 electrodes
Water Hardness — Range0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+)
Water Hardness — Resolution0.001, 0.01, 0.1, 1
Water Hardness — Accuracy±1% F.S.
Water Hardness — Calibration Points2to 5points 0.01, 0.1, 1, 10, 100mmol/L)
Temperature — Range0~105°C / 32~221°F
Temperature — Resolution0.1°C/0.1°F
Temperature — Accuracy±05°C/0.9°F
Temperature — Offset Calibration1 point, reading ±10°C
Other Specifications — Temperature Compensation0~100°C, manual or automatic
Other Specifications — Solution Temperature Coefficient25°C
Other Specifications — Stability CriteriaStandard or high-accuracy
Other Specifications — Calibration Due Alarm1to 31 days or off
ION-B131 — Benchtop pH Meter, 5 Calibration Point
pH — Range_
pH — Resolution_
pH — Accuracy_
pH — Calibration Points_
pH — Ph Buffer Options_
ORP — mV Range±2000.0mV
ORP — Relative mV Range_
ORP — Resolution0.1mV
ORP — Accuracy±0.2mV
ORP — Calibration Points_
Ion — Range0.001~30000 (depending on the range of ISE)
Ion — Resolution0.001, 0.01, 0.1, 1
Ion — Accuracy±0.5% F.S. (monovalent), ±1% F.S. (divalent))
Ion — Measurementppm, mg/L, mol/L, mmol/L
Ion — Unitsppm, mg/L, mol/L, mmol/L
Ion — Calibration Points2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000)
Ion — Measurement MethodsDirect reading, known addition, known subtraction, sample addition, sample subtraction
Ion — Electrode Management1 to 3 electrodes
Water Hardness — Range0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+)
Water Hardness — Resolution0.001,0.01,0.1,1
Water Hardness — Accuracy±1% F.S.
Water Hardness — Calibration Points2to 5points 0.01, 0.1, 1, 10, 100mmol/L)
Temperature — Range0~105°C/32~221°F
Temperature — Resolution0.1°C/0.1°F
Temperature — Accuracy±05°C/0.9°F
Temperature — Offset Calibration1 point, reading ±10°C
Other Specifications — Temperature Compensation0~100°C, manual or automatic
Other Specifications — Solution Temperature Coefficient_
Other Specifications — Stability CriteriaStandard or high-accuracy
Other Specifications — Calibration Due Alarm1to 31 days or off

Specification published by Scitek Global. Confirm the exact configuration on the written quotation before ordering.

Key features

What the range offers

  • 2 point key calibration, automatic recognition of standard buffers.
  • Optional USA or NIST standard buffer sets.
  • Automatic electrode slope display for prompt replacement of electrodes.
  • Lab benchtop pH meter with 1 to 3 points calibration, suitable for measuring pH and mV values in samples for daily experiments.
  • Automatic temperature compensation ensures measurement accuracy
  • Automatically recognizes USA and NIST standard buffers
  • Measurement accuracy of 0.01pH, suitable for most accurate measurements.
  • 5 parameters can be customized, including the number of calibration points, temperature, etc.
  • High resolution LCD display, 5.7 inches.
  • Multi-reading feature allows auto-read, timed-read and continuous-read.

Next step

Tell us the measurement and the range.

We will confirm the right model, the price and the lead time.

Message on WhatsApp