- Models
- TB-B200; MWQ-B900; MWQ-B901; MWQ-B902; MWQ-B903; MWQ-B904; PHC-B100; PHC-B100T; DO-PCB100; DO-PB100; DO-PCB100T; DO-PB100T; CON-DOB100; CON-DOB100T
- Turbidity — Measuring Range
- 0 to 2000 NTU/0 to 500 EBC/0 to 9999 ASBC
- Turbidity — Minimum Resolution (NTU)
- 0.01, 0.1, 1, automatic
- Turbidity — Accuracy
- ±2% of reading (0~500 NTU), ±3% of reading (501~2000 NTU)
- Turbidity — Calibration
- 2 to 7 points
This benchtop turbidimeter improves efficiency by being able to measure turbidity and TSS at the same time, increasing the efficiency of your experiments.
Added to your inquiry list. It travels with your next quote request.
14 models
Product Description
Benchtop Multiparameter Meter specification for every model we supply. Figures are the manufacturer’s published values.
| Specification | Value |
|---|---|
| TB-B200 — Multiparameter Benchtop Turbidimeter | |
| Turbidity — Measuring Range | 0 to 2000 NTU/0 to 500 EBC/0 to 9999 ASBC |
| Turbidity — Minimum Resolution (NTU) | 0.01, 0.1, 1, automatic |
| Turbidity — Accuracy | ±2% of reading (0~500 NTU), ±3% of reading (501~2000 NTU) |
| Turbidity — Calibration | 2 to 7 points |
| Turbidity — Calibration Standard | 0.02/10/200/500/1000/1500/ 2000 NTU |
| TSS — Range | Depending on the TSS conversion factor |
| TSS — Resolution | 0.1 / 1 |
| TSS — Accuracy | ±3% of reading |
| Other Specification — Light Source | Infrared-emitting diode, wavelength 850 nm |
| Other Specification — Detector | Silicon photodiode |
| Other Specification — Stray Light | < 0.02 NTU |
| Other Specification — Sample Vial | 60×25(Ø) mm |
| Other Specification — Sample Volume (ml) | 20 |
| Other Specification — Auto-Power Off | 2 hours after last key pressed |
| Other Specification — Memory | Stores up to 200 data sets |
| Other Specification — Output | USB communication interface |
| Other Specification — Display | 4.5 inches TFT LCD |
| Other Specification — Power Supply | 12V DC power adapter |
| Other Specification — Size(W×D×H)(mm) | 250x177x96 |
| Other Specification — Shipping Size (W×D×H)(mm) | 300x200x200 |
| Other Specification — N.W./G.W.(kg) | 1.2/1.5 |
| MWQ-B900 — Benchtop Multiparameter Water Quality Meter MWQ-B Series | |
| pH — Range | -2.000~20.000pH |
| pH — Resolution | 0.001, 0.01, 0.1pH, selectable |
| pH — Accuracy | ±0.002pH |
| pH — Calibration Points | 1 to 5 points |
| pH — pH Buffer Options | USA, NIST, DIN, 2 custom buffers |
| ORP — Range | ±1999.9mV |
| ORP — Resolution | 0.1, 1mV, selectable |
| ORP — Accuracy | ±0.2mV |
| ORP — Calibration Points | 1 point |
| Ion — Range | 0.001~19999 (depending on the range of ISE) |
| Ion — Resolution | 0.001, 0.01, 0.1, 1 |
| Ion — Accuracy | ±0.5% F.S. (monovalent), ±1% F.S. (divalent) |
| Ion — Measurement Units | ppm, mg/L, mol/L, mmol/L |
| Ion — Calibration Points | 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) |
| Conductivity — Range | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
| Conductivity — Resolution | 0.001,0.01,0.1,1 |
| Conductivity — Accuracy | ±0.5% F.S. |
| Conductivity — Calibration Points | 1 to 5 points |
| Conductivity — Calibration Solutions | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| Conductivity — Temperature Coefficient | Linear (0.0~10.0%/°C), pure water |
| Conductivity — Reference Temperature | 20/25°c |
| Conductivity — Cell Constant | K=0.1, 1, 10 or custom |
| TDS — Range | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
| TDS — Resolution | 0.01,0.1,1 |
| TDS — Accuracy | ±1% F.S. |
| TDS — TDS Factor | 0.1~1.0 (default 0.5) |
| Salinity — Range | 0.00~42.00psu, 0.00~80.00ppt |
| Salinity — Resolution | 0.01 |
| Salinity — Accuracy | ±1% F.S. |
| Resistivity — Range | 0.00~20.00MΩ |
| MWQ-B901 — Benchtop Multiparameter Water Quality Meter MWQ-B Series | |
| pH — Range | -2.000~20.000pH |
| pH — Resolution | 0.001, 0.01, 0.1pH, selectable |
| pH — Accuracy | ±0.002pH |
| pH — Calibration Points | 1 to 5 points |
| pH — pH Buffer Options | USA, NIST, DIN, 2 custom buffers |
| ORP — Range | ±1999.9mV |
| ORP — Resolution | 0.1, 1mV, selectable |
| ORP — Accuracy | ±0.2mV |
| ORP — Calibration Points | — |
| Ion — Range | — |
| Ion — Resolution | — |
| Ion — Accuracy | — |
| Ion — Measurement Units | — |
| Ion — Calibration Points | — |
| Conductivity — Range | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
| Conductivity — Resolution | 0.001,0.01,0.1,1 |
| Conductivity — Accuracy | ±0.5% F.S. |
| Conductivity — Calibration Points | 1 to 5 points |
| Conductivity — Calibration Solutions | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| Conductivity — Temperature Coefficient | Linear (0.0~10.0%/°C), pure water |
| Conductivity — Reference Temperature | 20/25°c |
| Conductivity — Cell Constant | K=0.1, 1, 10 or custom |
| TDS — Range | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
| TDS — Resolution | 0.01,0.1,1 |
| TDS — Accuracy | ±1% F.S. |
| TDS — TDS Factor | 0.1~1.0 (default 0.5) |
| Salinity — Range | — |
| Salinity — Resolution | — |
| Salinity — Accuracy | — |
| Resistivity — Range | — |
| MWQ-B902 — Benchtop Multiparameter Water Quality Meter MWQ-B Series | |
| pH — Range | -2.000~20.000pH |
| pH — Resolution | 0.001, 0.01, 0.1pH, selectable |
| pH — Accuracy | ±0.002pH |
| pH — Calibration Points | 1 to 5 points |
| pH — pH Buffer Options | USA, NIST, DIN, 2 custom buffers |
| ORP — Range | ±1999.9mV |
| ORP — Resolution | 0.1, 1mV, selectable |
| ORP — Accuracy | ±0.2mV |
| ORP — Calibration Points | 1 point |
| Ion — Range | — |
| Ion — Resolution | — |
| Ion — Accuracy | — |
| Ion — Measurement Units | — |
| Ion — Calibration Points | — |
| Conductivity — Range | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
| Conductivity — Resolution | 0.001,0.01,0.1,1 |
| Conductivity — Accuracy | ±0.5% F.S. |
| Conductivity — Calibration Points | 1 to 5 points |
| Conductivity — Calibration Solutions | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| Conductivity — Temperature Coefficient | Linear (0.0~10.0%/°C), pure water |
| Conductivity — Reference Temperature | 20/25°c |
| Conductivity — Cell Constant | K=0.1, 1, 10 or custom |
| TDS — Range | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
| TDS — Resolution | 0.01,0.1,1 |
| TDS — Accuracy | ±1% F.S. |
| TDS — TDS Factor | 0.1~1.0 (default 0.5) |
| Salinity — Range | 0.00~42.00psu, 0.00~80.00ppt |
| Salinity — Resolution | 0.01 |
| Salinity — Accuracy | ±1% F.S. |
| Resistivity — Range | 0.00~20.00MΩ |
| MWQ-B903 — Benchtop Multiparameter Water Quality Meter MWQ-B Series | |
| pH — Range | -2.000~20.000pH |
| pH — Resolution | 0.001, 0.01, 0.1pH, selectable |
| pH — Accuracy | ±0.002pH |
| pH — Calibration Points | 1 to 5 points |
| pH — pH Buffer Options | USA, NIST, DIN, 2 custom buffers |
| ORP — Range | ±1999.9mV |
| ORP — Resolution | 0.1, 1mV, selectable |
| ORP — Accuracy | ±0.2mV |
| ORP — Calibration Points | 1 point |
| Ion — Range | — |
| Ion — Resolution | — |
| Ion — Accuracy | — |
| Ion — Measurement Units | — |
| Ion — Calibration Points | — |
| Conductivity — Range | — |
| Conductivity — Resolution | — |
| Conductivity — Accuracy | — |
| Conductivity — Calibration Points | — |
| Conductivity — Calibration Solutions | — |
| Conductivity — Temperature Coefficient | — |
| Conductivity — Reference Temperature | — |
| Conductivity — Cell Constant | — |
| TDS — Range | — |
| TDS — Resolution | — |
| TDS — Accuracy | — |
| TDS — TDS Factor | — |
| Salinity — Range | — |
| Salinity — Resolution | — |
| Salinity — Accuracy | — |
| Resistivity — Range | — |
| MWQ-B904 — Benchtop Multiparameter Water Quality Meter MWQ-B Series | |
| pH — Range | — |
| pH — Resolution | — |
| pH — Accuracy | — |
| pH — Calibration Points | — |
| pH — pH Buffer Options | — |
| ORP — Range | — |
| ORP — Resolution | — |
| ORP — Accuracy | — |
| ORP — Calibration Points | — |
| Ion — Range | — |
| Ion — Resolution | — |
| Ion — Accuracy | — |
| Ion — Measurement Units | — |
| Ion — Calibration Points | — |
| Conductivity — Range | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
| Conductivity — Resolution | 0.001,0.01,0.1,1 |
| Conductivity — Accuracy | ±0.5% F.S. |
| Conductivity — Calibration Points | 1 to 5 points |
| Conductivity — Calibration Solutions | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| Conductivity — Temperature Coefficient | Linear (0.0~10.0%/°C), pure water |
| Conductivity — Reference Temperature | 20/25°c |
| Conductivity — Cell Constant | K=0.1, 1, 10 or custom |
| TDS — Range | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
| TDS — Resolution | 0.01,0.1,1 |
| TDS — Accuracy | ±1% F.S. |
| TDS — TDS Factor | 0.1~1.0 (default 0.5) |
| Salinity — Range | 0.00~42.00psu, 0.00~80.00ppt |
| Salinity — Resolution | 0.01 |
| Salinity — Accuracy | ±1% F.S. |
| Resistivity — Range | 0.00~20.00MΩ |
| PHC-B100 — Benchtop pH/Conductivity Meter, Automatic Calibration | |
| pH — Range | (-2.00-20.00) pH |
| pH — Resolution | 0.01/0.1 pH |
| pH — Accuracy | ±0.01pH ±1digit |
| pH — Auto. Temperature Compensation | -9.9℃~130℃(14.1~266)℉ |
| Cond. — Range | 0~200.0mS/cm, auto divided by range of: 0~19.999µS/cm 20.0~199.9µS/cm 200~1999µS/cm 2.00~19.99mS/cm 20.00~199.9mS/cm |
| Cond. — Range | TDS: 0 -100.0g/L |
| Cond. — Range | Resistivity: 5.00Ω·cm-100.0MΩ·cm |
| Cond. — Range | Salinity: 0-100.0 ppt |
| Cond. — Resolution | 0.001 |
| Cond. — Accuracy | ±1.0 % FS±1digit |
| mV (ORP Probe Optional) — Range | -1,999mV -+1,999mV |
| mV (ORP Probe Optional) — Resolution | ± 0.1/1mV |
| mV (ORP Probe Optional) — Accuracy | ±0.1% FS ±1digit |
| Temperature — Range | -9.9℃~130℃ (14.1~266)℉ |
| Temperature — Resolution/ Accuracy | 0.1℃; ±0.2℃ |
| Data Storage | 450groups |
| Data Output | 1. USB to Flash Disk |
| Data Output | 2. Wireless connection to printer (the printer is optional) |
| Power Supply | DC12V |
| Packing Including | 1. PHC-B100 Meter |
| Packing Including | 2. 201T ATC pH probe |
| Packing Including | 3. pH buffer solution: pH 4.00/7.00/10.01, 50mL, one for each |
| Packing Including | 4. CON201TG Glass Cond probe |
| Packing Including | 5. Standard Cond solution: 50mL: 84µS/1413µS/12.88mS/cm, one for each |
| Packing Including | 6. F01 Flexible probe holder: 1pc |
| Packing Including | 7. Power adaptor: 1pc |
| Packing Including | 8. A01 Power adaptor |
| Shipping Size (WxDxH)(mm) | 430x600x130 |
| N.W. / G.W. (kg) | 2.0 / 2.5 |
| PHC-B100T — Benchtop pH/Conductivity Meter, Touch-screen | |
| pH — Range | (-2.000-20.000) pH |
| pH — Resolution | 0.001/0.01 pH |
| pH — Accuracy | ±0.002pH ±1digit |
| pH — Auto. Temperature Compensation | -10.0~135℃ (14.0~275.0)℉ |
| Cond. — Range | 0~2000.0mS/cm, auto divided by range of: 0~19.999µS/cm 20.0~199.9µS/cm 200~1999µS/cm 2.00~19.99mS/cm 20.00~199.9mS/cm 200.0~2000mS/cm (K=10) the match test: 0-200.0mS/cm |
| Cond. — Resolution | 0.001 |
| Cond. — Accuracy | ±0.5 % FS±1digit |
| mV (ORP Probe Optional) — Range | -1, 999mV -+1, 999mV |
| mV (ORP Probe Optional) — Resolution | ± 0.1/1mV |
| mV (ORP Probe Optional) — Accuracy | ±0.03% FS ±1digit |
| Temperature — Range | -10.0~135℃(14.0~275.0)℉ |
| Temperature — Resolution/Accuracy | 0.1℃; ±0.2℃ |
| Data Storage | 5000 groups |
| Data Output | 1. USB to Flash Disk |
| Data Output | 2. USB to PC |
| Data Output | 3. Wireless connection to printer (the printer is optional) |
| Power Supply | DC12V |
| Packing Including | 1. PHC-B100T Meter |
| Packing Including | 2. 201G Refillable glass pH probe: 1pc |
| Packing Including | 3. Temp-01 Stainless steel probe: 1pc |
| Packing Including | 4. pH buffer solution: pH 4.00/7.00/10.01, 50mL, one for each |
| Packing Including | 5. CON201TG Glass ATC Cond probe, (K=1) |
| Packing Including | 6. Standard Cond solution: 50mL: 84µS/1413µS/12.88mS/cm, one for each |
| Packing Including | 7. F01 Flexible probe holder: 1pc |
| Packing Including | 8. Magnetic stirrer: 1pc |
| Packing Including | 9. PC cable: 1pc |
| Packing Including | 10. A01 Power adaptor |
| Shipping Size (WxDxH)(mm) | 430x600x130 |
| N.W. / G.W. (kg) | 2.5 / 3.1 |
| DO-PCB100 — Benchtop pH/Conductivity/Dissolved Oxygen Meter, Automatic Calibration | |
| pH — Range | (-2.00-20.00)pH |
| pH — Resolution | 0.01/0.1 pH |
| pH — Accuracy | ±0.01 pH ±1digit |
| pH — Auto. Temperature Compensation | -9.9℃~130℃ (14.1~266)℉ |
| Cond. — Range | 0~200.0mS/cm, auto divided by range of: 0~19.999µS/cm 20.0~199.9µS/cm 200~1999µS/cm 2.00~19.99mS/cm 20.00~199.9mS/cm |
| Cond. — Range | TDS: 0 -100.0g/L Resistivity: 5.00Ω·cm-100.0MΩ·cm, Salinity: 0-100.0 ppt |
| Cond. — Resolution | 0.001 |
| Cond. — Accuracy | ±1.0 % FS±1digit |
| DO — Range | 0-20.00 mg/L (ppm), 0-200.0 % |
| DO — Accuracy/ Resolution | ± 0.30 mg/L; 0.01 or 0.1 mg/L |
| DO — ATC Range | (0 - 50)℃ automatically |
| DO — Salinity Compensation | 0~45 ppt manual |
| DO — Barometric Compensation | 0~200 kPa automatically |
| Temperature — Range | -9.9℃~130℃ (14.1~266)℉ |
| Temperature — Resolution/Accuracy | 0.1℃; ±0.2℃ |
| Data Storage | 450groups |
| Data Output | 1. USB to Flash Disk |
| Data Output | 2. Wireless connection to printer (the printer is optional) |
| Power Supply | DC12V |
| Packing Including | 1. DO-PCB100 Meter |
| Packing Including | 2. 201T ATC pH probe |
| Packing Including | 3. pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each |
| Packing Including | 4. CON201TG Glass Cond probe, K=1.0 |
| Packing Including | 5. Standard Cond solution: 50mL: 84µS/1413µS/12.88mS/cm, one for each; |
| Packing Including | 6. DO01-2M Polarographic DO probe, cable length: 2m |
| Packing Including | 7. DOS-01 Membrane refill solution: 30mL,1pc |
| Packing Including | 8. DOSC Sensor caps: 3pcs/group, 1pkg |
| Packing Including | 9. F01 Flexible probe Holder: 1pc |
| Packing Including | 10. A01 Power adaptor:1pc |
| Shipping Size (WxDxH)(mm) | 430x600x130 |
| DO-PB100 — Benchtop pH/Dissolved Oxygen Meter, Automatic Calibration | |
| pH — Range | (-2.00-20.00) pH |
| pH — Resolution | 0.01/0.1 pH |
| pH — Accuracy | ±0.01pH ±1digit |
| pH — Auto. Temperature Compensation | -9.9℃~130℃(14.1~266)℉ |
| DO — Range | 0-20.00 mg/L (ppm), 0-200.0 % |
| DO — Accuracy/ Resolution | ± 0.30 mg/L; 0.01 or 0.1 mg/L |
| DO — ATC Range | (0 - 50)℃ automatically |
| DO — Salinity Compensation | 0~45 ppt manual |
| DO — Barometric Ccompensation | 0~200 kPa automatically |
| mV (ORP probe optional) — Range | -1, 999mV -+1, 999mV |
| mV (ORP probe optional) — Resolution | ± 0.1/1mV |
| mV (ORP probe optional) — Accuracy | ±0.1% FS ±1digit |
| Temperature — Range | -9.9℃~130℃ (14.1~266)℉ |
| Temperature — Resolution/Accuracy | 0.1℃; ±0.2℃ |
| Data Storage | 450groups |
| Data Output | 1. USB to Flash Disk |
| Data Output | 2. Wireless connection to printer (the printer is optional) |
| Power Supply | DC12V |
| Packing Including | 1. DO-PB100 Meter |
| Packing Including | 2. 201T ATC pH probe |
| Packing Including | 3. pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each |
| Packing Including | 4. DO01-2M Polarographic DO probe, cable length: 2m |
| Packing Including | 5. DOS-01 Membrane refill solution: 30mL,1pc |
| Packing Including | 6. DOSC Sensor caps: 3pcs/group, 1pkg |
| Packing Including | 7. F01 Flexible probe Holder: 1pc |
| Packing Including | 8. A01 Power adaptor: 1pc |
| Shipping Size (WxDxH)(mm) | 430x600x130 |
| N.W. / G.W. (kg) | 1.9 / 2.4 |
| DO-PCB100T — Benchtop pH/Conductivity/Dissolved Oxygen Meter, Touch-screen | |
| pH — Range | (-2.000-20.000) pH |
| pH — Resolution | 0.001/0.01 pH |
| pH — Accuracy | ±0.002pH ±1digit |
| pH — Auto. Temperature Compensation | DO-PCB100T |
| Cond. — Range | 0~2000.0mS/cm, auto divided by range of: 0~19.999µS/cm 20.0~199.9µS/cm 200~1999µS/cm 2.00~19.99mS/cm 20.00~199.9mS/cm 200.0~2000mS/cm (K=10) the match test: 0-200.0mS/cm |
| Cond. — Resolution | 0.001 |
| Cond. — Accuracy | ±0.5 % FS±1digit |
| DO — Range | 0-20.00 mg/L (ppm), 0-200.0 % |
| DO — Accuracy/Resolution | ± 0.30 mg/L; 0.01 or 0.1 mg/L |
| DO — ATC Range | (0 - 50)℃ automatically |
| DO — Salinity Compensation | 0~45 ppt manual |
| DO — Barometric Compensation | 0~200 kPa automatically |
| mV (ORP Probe Optional) — Range | -1, 999mV -+1, 999mV |
| mV (ORP Probe Optional) — Resolution | ± 0.1/1mV |
| mV (ORP Probe Optional) — Accuracy | ±0.03% FS ±1digit |
| Temperature — Range | -10.0~135℃(14.0~275.0)℉ |
| Temperature — Resolution/Accuracy | 0.1℃; ±0.2℃ |
| Data storage | 5000 groups |
| Data Output | 1. USB to Flash Disk |
| Data Output | 2. USB to PC |
| Data Output | 3. Wireless connection to printer (the printer is optional) |
| Power Supply | DC12V |
| Packing Including | 1. DO-PCB100T Meter |
| Packing Including | 2. 201G Refillable glass pH probe: 1pc |
| Packing Including | 3. Temp-01 Stainless steel probe: 1pc |
| Packing Including | 4. pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each |
| Packing Including | 5. CON201TG Glass ATC Cond probe, (K=1) |
| Packing Including | 6. Standard Cond solution: 50mL: 84µS/1413µS/12.88mS/cm, one for each |
| Packing Including | 7. DO01-2M Polarographic DO probe, cable length: 2m |
| Packing Including | 8. DOS-01 Membrane refill solution: 30mL,1pc |
| DO-PB100T — Benchtop pH/Dissolved Oxygen Meter, Touch-screen | |
| pH — Range | (-2.000-20.000) pH |
| pH — Resolution | 0.001/0.01 pH |
| pH — Accuracy | ±0.002pH ±1digit |
| pH — Auto. Temperature Compensation | -10.0~135℃ (14.0~275.0)℉ |
| DO — Range | 0-20.00 mg/L (ppm), 0-200.0% |
| DO — Accuracy/ Resolution | ± 0.30 mg/L; 0.01 or 0.1 mg/L |
| DO — ATC Range | (0 - 50)℃ automatically |
| DO — Salinity Compensation | 0~45 ppt manual |
| DO — Barometric Compensation | 0~200 kPa automatically |
| mV (ORP Probe Optional) — Range | -1, 999mV -+1, 999mV |
| mV (ORP Probe Optional) — Resolution | ± 0.1/1mV |
| mV (ORP Probe Optional) — Accuracy | ±0.03% FS ±1digit |
| Temperature — Range | -10.0~135℃ (14.0~275.0)℉ |
| Temperature — Resolution/ Accuracy | 0.1℃; ±0.2℃ |
| Data Storage | 5000 groups |
| Data Output | 1. USB to Flash Disk |
| Data Output | 2. USB to PC |
| Data Output | 3. Wireless connection to printer (the printer is optional) |
| Power Supply | DC12V |
| Packing Including | 1. DO-PB100T Meter |
| Packing Including | 2. 201G Refillable glass pH probe: 1pc |
| Packing Including | 3. Temp-01 Stainless steel probe: 1pc |
| Packing Including | 4. pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each |
| Packing Including | 5. DO01-2M Polarographic DO probe, cable length: 2m |
| Packing Including | 6. DOS-01 Membrane refill solution: 30mL,1pc |
| Packing Including | 7. DOSC Sensor caps: 3pcs/group, 1pkg |
| Packing Including | 8. F01 Flexible probe holder: 1pc |
| Packing Including | 9. Magnetic stirrer: 1pc |
| Packing Including | 10. PC cable: 1pc |
| Packing Including | 11. A01 Power adaptor |
| CON-DOB100 — Benchtop Conductivity/Dissolved Oxygen Meter CON-DOB100 | |
| Conductivity — Range | 0~200.0mS/cm, auto divided by range of: 0~19.999µS/cm; 20.0~199.9µS/cm; 200~1999µS/cm; 2.00~19.99mS/cm; 20.00~199.9mS/cm; TDS: 0 -100.0g/L Resistivity: 5.00Ω·cm-100.0MΩ·cm Salinity: 0-100.0 ppt |
| Conductivity — Resolution | 0.001 |
| Conductivity — Accuracy | ±1.0 % FS±1digit |
| DO — Range | 0-20.00 mg/L(ppm), 0-200.0 % |
| DO — Accuracy/Resolution | ± 0.30 mg/L; 0.01 or 0.1 mg/L |
| DO — ATC Range | (0 - 50)℃ automatically |
| DO — Salinity Compensation | 0~45 ppt manual |
| DO — Barometric Compensation | 0~200 kPa automatically |
| Temperature — Range | -9.9℃~130℃ (14.1~266)℉ |
| Temperature — Resolution/ Accuracy | 0.1℃; ±0.2℃ |
| Data Storage | 450 groups |
| Data Output | 1. USB to Flash Disk |
| Data Output | 2. Wireless connection to printer (the printer is optional) |
| Power supply | DC12V |
| Packing Including | 1. CON-DOB100 Meter |
| Packing Including | 2. CON201TG Glass Cond probe, K=1.0 |
| Packing Including | 3. Standard Cond solution: 50mL: 84µS/1413µS/ 12.88mS/cm, one for each; |
| Packing Including | 4. DO01-2M Polarographic DO probe, cable length: 2m |
| Packing Including | 5. DOS-01 Membrane refill solution: 30mL, 1pc |
| Packing Including | 6. DOSC Sensor caps: 3pcs/group, 1pkg |
| Packing Including | 7. F01 Flexible probe Holder: 1pc |
| Packing Including | 8. A01 Power adaptor: 1pc |
| Shipping Size (WxDxH)(mm) | 430x600x130 |
| N.W. / G.W. (kg) | 1.8 / 2.3 |
| CON-DOB100T — Benchtop Conductivity/Dissolved Oxygen Meter, Touch-screen | |
| Cond. — Range | 0~2000.0mS/cm, auto divided by range of: 0~19.999µS/cm 20.0~199.9µS/cm 200~1999µS/cm 2.00~19.99mS/cm 20.00~199.9mS/cm 200.0~2000mS/cm(K=10) the match test: 0-200.0mS/cm |
| Cond. — Resolution | 0.001 |
| Cond. — Accuracy | ±0.5 % FS±1digit |
| DO — Range | 0-20.00 mg/L (ppm), 0-200.0 % |
| DO — Accuracy/Resolution | ± 0.30 mg/L; 0.01 or 0.1 mg/L |
| DO — ATC Range | (0 - 50)℃ automatically |
| DO — Salinity Compensation | 0~45 ppt manual |
| DO — Barometric Compensation | 0~200 kPa automatically |
| Temperature — Range | -10.0~135℃(14.0~275.0)℉ |
| Temperature — Resolution/Accuracy | 0.1℃; ±0.2℃ |
| Data Storage | 5000 groups |
| Data Output | 1. USB to Flash Disk |
| Data Output | 2. USB to PC |
| Data Output | 3. Wireless connection to printer (the printer is optional) |
| Power Supply | DC12V |
| Packing Including | 1. CON-DOB100T Meter |
| Packing Including | 2. CON201TG Glass ATC Cond probe, (K=1) |
| Packing Including | 3. Standard Cond solution: 50mL: 84µS/1413µS/12.88mS/cm, one for each |
| Packing Including | 4. DO01-2M Polarographic DO probe, cable length: 2m |
| Packing Including | 5. DOS-01 Membrane refill solution: 30mL,1pc |
| Packing Including | 6. DOSC Sensor caps: 3pcs/group, 1pkg |
| Packing Including | 7. F01 Flexible probe holder: 1pc |
| Packing Including | 8. Magnetic stirrer: 1pc |
| Packing Including | 9. PC cable: 1pc |
| Packing Including | 10. A01 Power adaptor: 1pc |
| Shipping Size (WxDxH)(mm) | 430x600x130 |
| N.W. / G.W. (kg) | 2.3 / 3 |
Specification published by Scitek Global. Confirm the exact configuration on the written quotation before ordering.
Key features
What the range offers
- Multiparameter benchtop turbidimeter is equipped with a 4.5 inches TFT display.
- 2 to 7 points calibration using the Formazin Standards.
- Selectable 4 turbidity units, including the NTU, FNU, EBC and ASBC.
- TSS conversion factor ensures the accurate measurement of total suspended solids.
- Auto-read function senses and locks a stable reading.
- Setup menu allows setting the date and time, measurement mode, resolution, auto-power off, etc.
- Password protection prevents the unauthorized calibration and settings.
- Expanded memory stores or recalls up to 200 data sets.
- Reset function automatically resumes all settings back to the factory defaults.
- USB communication interface enables easy transfer of data from the meter to a PC.
Applications
Where it is used
- Industrial wastewater plants
- Municipal water and other industrial applications
Next step
Tell us the measurement and the range.
We will confirm the right model, the price and the lead time.