Authorized distributor · Karachi

Home/Products/Scitek Global/Benchtop Multiparameter Meter

Scitek Global Weighing & measurement

Benchtop Multiparameter Meter

Models
TB-B200; MWQ-B900; MWQ-B901; MWQ-B902; MWQ-B903; MWQ-B904; PHC-B100; PHC-B100T; DO-PCB100; DO-PB100; DO-PCB100T; DO-PB100T; CON-DOB100; CON-DOB100T
Turbidity — Measuring Range
0 to 2000 NTU/0 to 500 EBC/0 to 9999 ASBC
Turbidity — Minimum Resolution (NTU)
0.01, 0.1, 1, automatic
Turbidity — Accuracy
±2% of reading (0~500 NTU), ±3% of reading (501~2000 NTU)
Turbidity — Calibration
2 to 7 points

This benchtop turbidimeter improves efficiency by being able to measure turbidity and TSS at the same time, increasing the efficiency of your experiments.

Scitek Global 14 models

Product Description

Benchtop Multiparameter Meter specification for every model we supply. Figures are the manufacturer’s published values.

Benchtop Multiparameter Meter specification, by model, as published by Scitek Global
SpecificationValue
TB-B200 — Multiparameter Benchtop Turbidimeter
Turbidity — Measuring Range0 to 2000 NTU/0 to 500 EBC/0 to 9999 ASBC
Turbidity — Minimum Resolution (NTU)0.01, 0.1, 1, automatic
Turbidity — Accuracy±2% of reading (0~500 NTU), ±3% of reading (501~2000 NTU)
Turbidity — Calibration2 to 7 points
Turbidity — Calibration Standard0.02/10/200/500/1000/1500/ 2000 NTU
TSS — RangeDepending on the TSS conversion factor
TSS — Resolution0.1 / 1
TSS — Accuracy±3% of reading
Other Specification — Light SourceInfrared-emitting diode, wavelength 850 nm
Other Specification — DetectorSilicon photodiode
Other Specification — Stray Light< 0.02 NTU
Other Specification — Sample Vial60×25(Ø) mm
Other Specification — Sample Volume (ml)20
Other Specification — Auto-Power Off2 hours after last key pressed
Other Specification — MemoryStores up to 200 data sets
Other Specification — OutputUSB communication interface
Other Specification — Display4.5 inches TFT LCD
Other Specification — Power Supply12V DC power adapter
Other Specification — Size(W×D×H)(mm)250x177x96
Other Specification — Shipping Size (W×D×H)(mm)300x200x200
Other Specification — N.W./G.W.(kg)1.2/1.5
MWQ-B900 — Benchtop Multiparameter Water Quality Meter MWQ-B Series
pH — Range-2.000~20.000pH
pH — Resolution0.001, 0.01, 0.1pH, selectable
pH — Accuracy±0.002pH
pH — Calibration Points1 to 5 points
pH — pH Buffer OptionsUSA, NIST, DIN, 2 custom buffers
ORP — Range±1999.9mV
ORP — Resolution0.1, 1mV, selectable
ORP — Accuracy±0.2mV
ORP — Calibration Points1 point
Ion — Range0.001~19999 (depending on the range of ISE)
Ion — Resolution0.001, 0.01, 0.1, 1
Ion — Accuracy±0.5% F.S. (monovalent), ±1% F.S. (divalent)
Ion — Measurement Unitsppm, mg/L, mol/L, mmol/L
Ion — Calibration Points2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000)
Conductivity — Range0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Conductivity — Resolution0.001,0.01,0.1,1
Conductivity — Accuracy±0.5% F.S.
Conductivity — Calibration Points1 to 5 points
Conductivity — Calibration Solutions10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
Conductivity — Temperature CoefficientLinear (0.0~10.0%/°C), pure water
Conductivity — Reference Temperature20/25°c
Conductivity — Cell ConstantK=0.1, 1, 10 or custom
TDS — Range0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
TDS — Resolution0.01,0.1,1
TDS — Accuracy±1% F.S.
TDS — TDS Factor0.1~1.0 (default 0.5)
Salinity — Range0.00~42.00psu, 0.00~80.00ppt
Salinity — Resolution0.01
Salinity — Accuracy±1% F.S.
Resistivity — Range0.00~20.00MΩ
MWQ-B901 — Benchtop Multiparameter Water Quality Meter MWQ-B Series
pH — Range-2.000~20.000pH
pH — Resolution0.001, 0.01, 0.1pH, selectable
pH — Accuracy±0.002pH
pH — Calibration Points1 to 5 points
pH — pH Buffer OptionsUSA, NIST, DIN, 2 custom buffers
ORP — Range±1999.9mV
ORP — Resolution0.1, 1mV, selectable
ORP — Accuracy±0.2mV
ORP — Calibration Points—
Ion — Range—
Ion — Resolution—
Ion — Accuracy—
Ion — Measurement Units—
Ion — Calibration Points—
Conductivity — Range0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Conductivity — Resolution0.001,0.01,0.1,1
Conductivity — Accuracy±0.5% F.S.
Conductivity — Calibration Points1 to 5 points
Conductivity — Calibration Solutions10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
Conductivity — Temperature CoefficientLinear (0.0~10.0%/°C), pure water
Conductivity — Reference Temperature20/25°c
Conductivity — Cell ConstantK=0.1, 1, 10 or custom
TDS — Range0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
TDS — Resolution0.01,0.1,1
TDS — Accuracy±1% F.S.
TDS — TDS Factor0.1~1.0 (default 0.5)
Salinity — Range—
Salinity — Resolution—
Salinity — Accuracy—
Resistivity — Range—
MWQ-B902 — Benchtop Multiparameter Water Quality Meter MWQ-B Series
pH — Range-2.000~20.000pH
pH — Resolution0.001, 0.01, 0.1pH, selectable
pH — Accuracy±0.002pH
pH — Calibration Points1 to 5 points
pH — pH Buffer OptionsUSA, NIST, DIN, 2 custom buffers
ORP — Range±1999.9mV
ORP — Resolution0.1, 1mV, selectable
ORP — Accuracy±0.2mV
ORP — Calibration Points1 point
Ion — Range—
Ion — Resolution—
Ion — Accuracy—
Ion — Measurement Units—
Ion — Calibration Points—
Conductivity — Range0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Conductivity — Resolution0.001,0.01,0.1,1
Conductivity — Accuracy±0.5% F.S.
Conductivity — Calibration Points1 to 5 points
Conductivity — Calibration Solutions10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
Conductivity — Temperature CoefficientLinear (0.0~10.0%/°C), pure water
Conductivity — Reference Temperature20/25°c
Conductivity — Cell ConstantK=0.1, 1, 10 or custom
TDS — Range0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
TDS — Resolution0.01,0.1,1
TDS — Accuracy±1% F.S.
TDS — TDS Factor0.1~1.0 (default 0.5)
Salinity — Range0.00~42.00psu, 0.00~80.00ppt
Salinity — Resolution0.01
Salinity — Accuracy±1% F.S.
Resistivity — Range0.00~20.00MΩ
MWQ-B903 — Benchtop Multiparameter Water Quality Meter MWQ-B Series
pH — Range-2.000~20.000pH
pH — Resolution0.001, 0.01, 0.1pH, selectable
pH — Accuracy±0.002pH
pH — Calibration Points1 to 5 points
pH — pH Buffer OptionsUSA, NIST, DIN, 2 custom buffers
ORP — Range±1999.9mV
ORP — Resolution0.1, 1mV, selectable
ORP — Accuracy±0.2mV
ORP — Calibration Points1 point
Ion — Range—
Ion — Resolution—
Ion — Accuracy—
Ion — Measurement Units—
Ion — Calibration Points—
Conductivity — Range—
Conductivity — Resolution—
Conductivity — Accuracy—
Conductivity — Calibration Points—
Conductivity — Calibration Solutions—
Conductivity — Temperature Coefficient—
Conductivity — Reference Temperature—
Conductivity — Cell Constant—
TDS — Range—
TDS — Resolution—
TDS — Accuracy—
TDS — TDS Factor—
Salinity — Range—
Salinity — Resolution—
Salinity — Accuracy—
Resistivity — Range—
MWQ-B904 — Benchtop Multiparameter Water Quality Meter MWQ-B Series
pH — Range—
pH — Resolution—
pH — Accuracy—
pH — Calibration Points—
pH — pH Buffer Options—
ORP — Range—
ORP — Resolution—
ORP — Accuracy—
ORP — Calibration Points—
Ion — Range—
Ion — Resolution—
Ion — Accuracy—
Ion — Measurement Units—
Ion — Calibration Points—
Conductivity — Range0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Conductivity — Resolution0.001,0.01,0.1,1
Conductivity — Accuracy±0.5% F.S.
Conductivity — Calibration Points1 to 5 points
Conductivity — Calibration Solutions10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
Conductivity — Temperature CoefficientLinear (0.0~10.0%/°C), pure water
Conductivity — Reference Temperature20/25°c
Conductivity — Cell ConstantK=0.1, 1, 10 or custom
TDS — Range0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
TDS — Resolution0.01,0.1,1
TDS — Accuracy±1% F.S.
TDS — TDS Factor0.1~1.0 (default 0.5)
Salinity — Range0.00~42.00psu, 0.00~80.00ppt
Salinity — Resolution0.01
Salinity — Accuracy±1% F.S.
Resistivity — Range0.00~20.00MΩ
PHC-B100 — Benchtop pH/Conductivity Meter, Automatic Calibration
pH — Range(-2.00-20.00) pH
pH — Resolution0.01/0.1 pH
pH — Accuracy±0.01pH ±1digit
pH — Auto. Temperature Compensation-9.9℃~130℃(14.1~266)℉
Cond. — Range0~200.0mS/cm, auto divided by range of: 0~19.999µS/cm 20.0~199.9µS/cm 200~1999µS/cm 2.00~19.99mS/cm 20.00~199.9mS/cm
Cond. — RangeTDS: 0 -100.0g/L
Cond. — RangeResistivity: 5.00Ω·cm-100.0MΩ·cm
Cond. — RangeSalinity: 0-100.0 ppt
Cond. — Resolution0.001
Cond. — Accuracy±1.0 % FS±1digit
mV (ORP Probe Optional) — Range-1,999mV -+1,999mV
mV (ORP Probe Optional) — Resolution± 0.1/1mV
mV (ORP Probe Optional) — Accuracy±0.1% FS ±1digit
Temperature — Range-9.9℃~130℃ (14.1~266)℉
Temperature — Resolution/ Accuracy0.1℃; ±0.2℃
Data Storage450groups
Data Output1. USB to Flash Disk
Data Output2. Wireless connection to printer (the printer is optional)
Power SupplyDC12V
Packing Including1. PHC-B100 Meter
Packing Including2. 201T ATC pH probe
Packing Including3. pH buffer solution: pH 4.00/7.00/10.01, 50mL, one for each
Packing Including4. CON201TG Glass Cond probe
Packing Including5. Standard Cond solution: 50mL: 84µS/1413µS/12.88mS/cm, one for each
Packing Including6. F01 Flexible probe holder: 1pc
Packing Including7. Power adaptor: 1pc
Packing Including8. A01 Power adaptor
Shipping Size (WxDxH)(mm)430x600x130
N.W. / G.W. (kg)2.0 / 2.5
PHC-B100T — Benchtop pH/Conductivity Meter, Touch-screen
pH — Range(-2.000-20.000) pH
pH — Resolution0.001/0.01 pH
pH — Accuracy±0.002pH ±1digit
pH — Auto. Temperature Compensation-10.0~135℃ (14.0~275.0)℉
Cond. — Range0~2000.0mS/cm, auto divided by range of: 0~19.999µS/cm 20.0~199.9µS/cm 200~1999µS/cm 2.00~19.99mS/cm 20.00~199.9mS/cm 200.0~2000mS/cm (K=10) the match test: 0-200.0mS/cm
Cond. — Resolution0.001
Cond. — Accuracy±0.5 % FS±1digit
mV (ORP Probe Optional) — Range-1, 999mV -+1, 999mV
mV (ORP Probe Optional) — Resolution± 0.1/1mV
mV (ORP Probe Optional) — Accuracy±0.03% FS ±1digit
Temperature — Range-10.0~135℃(14.0~275.0)℉
Temperature — Resolution/Accuracy0.1℃; ±0.2℃
Data Storage5000 groups
Data Output1. USB to Flash Disk
Data Output2. USB to PC
Data Output3. Wireless connection to printer (the printer is optional)
Power SupplyDC12V
Packing Including1. PHC-B100T Meter
Packing Including2. 201G Refillable glass pH probe: 1pc
Packing Including3. Temp-01 Stainless steel probe: 1pc
Packing Including4. pH buffer solution: pH 4.00/7.00/10.01, 50mL, one for each
Packing Including5. CON201TG Glass ATC Cond probe, (K=1)
Packing Including6. Standard Cond solution: 50mL: 84µS/1413µS/12.88mS/cm, one for each
Packing Including7. F01 Flexible probe holder: 1pc
Packing Including8. Magnetic stirrer: 1pc
Packing Including9. PC cable: 1pc
Packing Including10. A01 Power adaptor
Shipping Size (WxDxH)(mm)430x600x130
N.W. / G.W. (kg)2.5 / 3.1
DO-PCB100 — Benchtop pH/Conductivity/Dissolved Oxygen Meter, Automatic Calibration
pH — Range(-2.00-20.00)pH
pH — Resolution0.01/0.1 pH
pH — Accuracy±0.01 pH ±1digit
pH — Auto. Temperature Compensation-9.9℃~130℃ (14.1~266)℉
Cond. — Range0~200.0mS/cm, auto divided by range of: 0~19.999µS/cm 20.0~199.9µS/cm 200~1999µS/cm 2.00~19.99mS/cm 20.00~199.9mS/cm
Cond. — RangeTDS: 0 -100.0g/L Resistivity: 5.00Ω·cm-100.0MΩ·cm, Salinity: 0-100.0 ppt
Cond. — Resolution0.001
Cond. — Accuracy±1.0 % FS±1digit
DO — Range0-20.00 mg/L (ppm), 0-200.0 %
DO — Accuracy/ Resolution± 0.30 mg/L; 0.01 or 0.1 mg/L
DO — ATC Range(0 - 50)℃ automatically
DO — Salinity Compensation0~45 ppt manual
DO — Barometric Compensation0~200 kPa automatically
Temperature — Range-9.9℃~130℃ (14.1~266)℉
Temperature — Resolution/Accuracy0.1℃; ±0.2℃
Data Storage450groups
Data Output1. USB to Flash Disk
Data Output2. Wireless connection to printer (the printer is optional)
Power SupplyDC12V
Packing Including1. DO-PCB100 Meter
Packing Including2. 201T ATC pH probe
Packing Including3. pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each
Packing Including4. CON201TG Glass Cond probe, K=1.0
Packing Including5. Standard Cond solution: 50mL: 84µS/1413µS/12.88mS/cm, one for each;
Packing Including6. DO01-2M Polarographic DO probe, cable length: 2m
Packing Including7. DOS-01 Membrane refill solution: 30mL,1pc
Packing Including8. DOSC Sensor caps: 3pcs/group, 1pkg
Packing Including9. F01 Flexible probe Holder: 1pc
Packing Including10. A01 Power adaptor:1pc
Shipping Size (WxDxH)(mm)430x600x130
DO-PB100 — Benchtop pH/Dissolved Oxygen Meter, Automatic Calibration
pH — Range(-2.00-20.00) pH
pH — Resolution0.01/0.1 pH
pH — Accuracy±0.01pH ±1digit
pH — Auto. Temperature Compensation-9.9℃~130℃(14.1~266)℉
DO — Range0-20.00 mg/L (ppm), 0-200.0 %
DO — Accuracy/ Resolution± 0.30 mg/L; 0.01 or 0.1 mg/L
DO — ATC Range(0 - 50)℃ automatically
DO — Salinity Compensation0~45 ppt manual
DO — Barometric Ccompensation0~200 kPa automatically
mV (ORP probe optional) — Range-1, 999mV -+1, 999mV
mV (ORP probe optional) — Resolution± 0.1/1mV
mV (ORP probe optional) — Accuracy±0.1% FS ±1digit
Temperature — Range-9.9℃~130℃ (14.1~266)℉
Temperature — Resolution/Accuracy0.1℃; ±0.2℃
Data Storage450groups
Data Output1. USB to Flash Disk
Data Output2. Wireless connection to printer (the printer is optional)
Power SupplyDC12V
Packing Including1. DO-PB100 Meter
Packing Including2. 201T ATC pH probe
Packing Including3. pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each
Packing Including4. DO01-2M Polarographic DO probe, cable length: 2m
Packing Including5. DOS-01 Membrane refill solution: 30mL,1pc
Packing Including6. DOSC Sensor caps: 3pcs/group, 1pkg
Packing Including7. F01 Flexible probe Holder: 1pc
Packing Including8. A01 Power adaptor: 1pc
Shipping Size (WxDxH)(mm)430x600x130
N.W. / G.W. (kg)1.9 / 2.4
DO-PCB100T — Benchtop pH/Conductivity/Dissolved Oxygen Meter, Touch-screen
pH — Range(-2.000-20.000) pH
pH — Resolution0.001/0.01 pH
pH — Accuracy±0.002pH ±1digit
pH — Auto. Temperature CompensationDO-PCB100T
Cond. — Range0~2000.0mS/cm, auto divided by range of: 0~19.999µS/cm 20.0~199.9µS/cm 200~1999µS/cm 2.00~19.99mS/cm 20.00~199.9mS/cm 200.0~2000mS/cm (K=10) the match test: 0-200.0mS/cm
Cond. — Resolution0.001
Cond. — Accuracy±0.5 % FS±1digit
DO — Range0-20.00 mg/L (ppm), 0-200.0 %
DO — Accuracy/Resolution± 0.30 mg/L; 0.01 or 0.1 mg/L
DO — ATC Range(0 - 50)℃ automatically
DO — Salinity Compensation0~45 ppt manual
DO — Barometric Compensation0~200 kPa automatically
mV (ORP Probe Optional) — Range-1, 999mV -+1, 999mV
mV (ORP Probe Optional) — Resolution± 0.1/1mV
mV (ORP Probe Optional) — Accuracy±0.03% FS ±1digit
Temperature — Range-10.0~135℃(14.0~275.0)℉
Temperature — Resolution/Accuracy0.1℃; ±0.2℃
Data storage5000 groups
Data Output1. USB to Flash Disk
Data Output2. USB to PC
Data Output3. Wireless connection to printer (the printer is optional)
Power SupplyDC12V
Packing Including1. DO-PCB100T Meter
Packing Including2. 201G Refillable glass pH probe: 1pc
Packing Including3. Temp-01 Stainless steel probe: 1pc
Packing Including4. pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each
Packing Including5. CON201TG Glass ATC Cond probe, (K=1)
Packing Including6. Standard Cond solution: 50mL: 84µS/1413µS/12.88mS/cm, one for each
Packing Including7. DO01-2M Polarographic DO probe, cable length: 2m
Packing Including8. DOS-01 Membrane refill solution: 30mL,1pc
DO-PB100T — Benchtop pH/Dissolved Oxygen Meter, Touch-screen
pH — Range(-2.000-20.000) pH
pH — Resolution0.001/0.01 pH
pH — Accuracy±0.002pH ±1digit
pH — Auto. Temperature Compensation-10.0~135℃ (14.0~275.0)℉
DO — Range0-20.00 mg/L (ppm), 0-200.0%
DO — Accuracy/ Resolution± 0.30 mg/L; 0.01 or 0.1 mg/L
DO — ATC Range(0 - 50)℃ automatically
DO — Salinity Compensation0~45 ppt manual
DO — Barometric Compensation0~200 kPa automatically
mV (ORP Probe Optional) — Range-1, 999mV -+1, 999mV
mV (ORP Probe Optional) — Resolution± 0.1/1mV
mV (ORP Probe Optional) — Accuracy±0.03% FS ±1digit
Temperature — Range-10.0~135℃ (14.0~275.0)℉
Temperature — Resolution/ Accuracy0.1℃; ±0.2℃
Data Storage5000 groups
Data Output1. USB to Flash Disk
Data Output2. USB to PC
Data Output3. Wireless connection to printer (the printer is optional)
Power SupplyDC12V
Packing Including1. DO-PB100T Meter
Packing Including2. 201G Refillable glass pH probe: 1pc
Packing Including3. Temp-01 Stainless steel probe: 1pc
Packing Including4. pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each
Packing Including5. DO01-2M Polarographic DO probe, cable length: 2m
Packing Including6. DOS-01 Membrane refill solution: 30mL,1pc
Packing Including7. DOSC Sensor caps: 3pcs/group, 1pkg
Packing Including8. F01 Flexible probe holder: 1pc
Packing Including9. Magnetic stirrer: 1pc
Packing Including10. PC cable: 1pc
Packing Including11. A01 Power adaptor
CON-DOB100 — Benchtop Conductivity/Dissolved Oxygen Meter CON-DOB100
Conductivity — Range0~200.0mS/cm, auto divided by range of: 0~19.999µS/cm; 20.0~199.9µS/cm; 200~1999µS/cm; 2.00~19.99mS/cm; 20.00~199.9mS/cm; TDS: 0 -100.0g/L Resistivity: 5.00Ω·cm-100.0MΩ·cm Salinity: 0-100.0 ppt
Conductivity — Resolution0.001
Conductivity — Accuracy±1.0 % FS±1digit
DO — Range0-20.00 mg/L(ppm), 0-200.0 %
DO — Accuracy/Resolution± 0.30 mg/L; 0.01 or 0.1 mg/L
DO — ATC Range(0 - 50)℃ automatically
DO — Salinity Compensation0~45 ppt manual
DO — Barometric Compensation0~200 kPa automatically
Temperature — Range-9.9℃~130℃ (14.1~266)℉
Temperature — Resolution/ Accuracy0.1℃; ±0.2℃
Data Storage450 groups
Data Output1. USB to Flash Disk
Data Output2. Wireless connection to printer (the printer is optional)
Power supplyDC12V
Packing Including1. CON-DOB100 Meter
Packing Including2. CON201TG Glass Cond probe, K=1.0
Packing Including3. Standard Cond solution: 50mL: 84µS/1413µS/ 12.88mS/cm, one for each;
Packing Including4. DO01-2M Polarographic DO probe, cable length: 2m
Packing Including5. DOS-01 Membrane refill solution: 30mL, 1pc
Packing Including6. DOSC Sensor caps: 3pcs/group, 1pkg
Packing Including7. F01 Flexible probe Holder: 1pc
Packing Including8. A01 Power adaptor: 1pc
Shipping Size (WxDxH)(mm)430x600x130
N.W. / G.W. (kg)1.8 / 2.3
CON-DOB100T — Benchtop Conductivity/Dissolved Oxygen Meter, Touch-screen
Cond. — Range0~2000.0mS/cm, auto divided by range of: 0~19.999µS/cm 20.0~199.9µS/cm 200~1999µS/cm 2.00~19.99mS/cm 20.00~199.9mS/cm 200.0~2000mS/cm(K=10) the match test: 0-200.0mS/cm
Cond. — Resolution0.001
Cond. — Accuracy±0.5 % FS±1digit
DO — Range0-20.00 mg/L (ppm), 0-200.0 %
DO — Accuracy/Resolution± 0.30 mg/L; 0.01 or 0.1 mg/L
DO — ATC Range(0 - 50)℃ automatically
DO — Salinity Compensation0~45 ppt manual
DO — Barometric Compensation0~200 kPa automatically
Temperature — Range-10.0~135℃(14.0~275.0)℉
Temperature — Resolution/Accuracy0.1℃; ±0.2℃
Data Storage5000 groups
Data Output1. USB to Flash Disk
Data Output2. USB to PC
Data Output3. Wireless connection to printer (the printer is optional)
Power SupplyDC12V
Packing Including1. CON-DOB100T Meter
Packing Including2. CON201TG Glass ATC Cond probe, (K=1)
Packing Including3. Standard Cond solution: 50mL: 84µS/1413µS/12.88mS/cm, one for each
Packing Including4. DO01-2M Polarographic DO probe, cable length: 2m
Packing Including5. DOS-01 Membrane refill solution: 30mL,1pc
Packing Including6. DOSC Sensor caps: 3pcs/group, 1pkg
Packing Including7. F01 Flexible probe holder: 1pc
Packing Including8. Magnetic stirrer: 1pc
Packing Including9. PC cable: 1pc
Packing Including10. A01 Power adaptor: 1pc
Shipping Size (WxDxH)(mm)430x600x130
N.W. / G.W. (kg)2.3 / 3

Specification published by Scitek Global. Confirm the exact configuration on the written quotation before ordering.

Key features

What the range offers

  • Multiparameter benchtop turbidimeter is equipped with a 4.5 inches TFT display.
  • 2 to 7 points calibration using the Formazin Standards.
  • Selectable 4 turbidity units, including the NTU, FNU, EBC and ASBC.
  • TSS conversion factor ensures the accurate measurement of total suspended solids.
  • Auto-read function senses and locks a stable reading.
  • Setup menu allows setting the date and time, measurement mode, resolution, auto-power off, etc.
  • Password protection prevents the unauthorized calibration and settings.
  • Expanded memory stores or recalls up to 200 data sets.
  • Reset function automatically resumes all settings back to the factory defaults.
  • USB communication interface enables easy transfer of data from the meter to a PC.

Applications

Where it is used

  • Industrial wastewater plants
  • Municipal water and other industrial applications

Next step

Tell us the measurement and the range.

We will confirm the right model, the price and the lead time.

Message on WhatsApp