Models
DO-B100; DO-B810; DO-B980; DO-B100T
DO — Range
0-20.00 mg/L (ppm), 0-200.0 %
DO — Accuracy/Resolution
± 0.30 mg/L; 0.01 or 0.1 mg/L
DO — ATC range
(0 - 50)℃ automatically
DO — Salinity Compensation
0~45 ppt manual

This benchtop dissolved oxygen meter is widely used in laboratories, water treatment plants, aquaculture, etc.

Scitek Global 4 models

Product Description

Benchtop Dissolved Oxygen Meter specification for every model we supply. Figures are the manufacturer’s published values.

Benchtop Dissolved Oxygen Meter specification, by model, as published by Scitek Global
SpecificationValue
DO-B100 — Benchtop Dissolved Oxygen Meter, Automatic Calibration
DO — Range0-20.00 mg/L (ppm), 0-200.0 %
DO — Accuracy/Resolution± 0.30 mg/L; 0.01 or 0.1 mg/L
DO — ATC range(0 - 50)℃ automatically
DO — Salinity Compensation0~45 ppt manual
DO — Barometric Compensation0~200 kPa automatically
Temperature — Range-9.9℃~130℃ (14.1~266)℉
Temperature — Resolution/Accuracy0.1℃; ±0.2℃
Data Storage450groups
Data Output1. USB to Flash Disk
Data Output2. Wireless connection to printer (the printer is optional)
Power SupplyDC12V
Packing Including1. DO-B100 Meter
Packing Including2. DO01-2M Polarographic DO probe, cable length: 2m
Packing Including3. DOS-01 Membrane refill solution: 30mL,1pc
Packing Including4. DOSC Sensor caps: 3pcs/group, 1pkg
Packing Including5. F01 Flexible probe Holder: 1pc
Packing Including6. A01 Power adaptor: 1pc
Shipping Size (WxDxH)(mm)330x540x130
N.W. / G.W. (kg)1.6 / 2.1
DO-B810 — Benchtop Dissolved Oxygen Meter B810
DO — Range0.0-20.0mg/L or ppm
DO — Resolution0.1mg/L
DO — Accuracy±0.5mg/L
Saturation — Range0.0~200.0%
Saturation — Resolution0.001
Saturation — Accuracy±2.0%
Temperature — Range0~60°C/32~140°F
Temperature — Resolution0.1°C/0.1°F
Temperature — Accuracy±1°C/±1.8°F
Temperature — Offset Calibration1 point, reading ±10℃
Other Specifications — Dissolved Oxygen Calibration1 or 2 points
Other Specifications — Temperature Compensation0~40°C, automatic
Other Specifications — Barometric Pressure Correction60.0~112.5kPa/450-850mmHg. manual
Other Specifications — Salinity Correction0.0-35.0g/L, manual
Other Specifications — Stability Criteria一
Other Specifications — Calibration Due Alarm一
Other Specifications — Hold FunctionManual or auto-endpoint
Other Specifications — Memory一
Other Specifications — Communication Interface一
Other Specifications — Connector6-pin nimi-DIN
Other Specifications — DisplayCustom LCD(120×60mm)
Other Specifications — Power RequirementsDC9V power adapter
Other Specifications — Sizes (W×D×H)210×205×75
Other Specifications — Shipping Size (W×D×H)(mm)300x250x200
Other Specifications — N.W./G.W. (kg)1.5/2
DO-B980 — Benchtop Dissolved Oxygen Meter B980
DO — Range0.00-20.00mg/L or ppm
DO — Resolution0.01,0.1mgL, selectable
DO — Accuracy±0.2mg/L
Saturation — Range0.0-200.0%
Saturation — Resolution0.1,1%, selectable
Saturation — Accuracy±2.0%
Temperature — Range0~60°C/32~140°F
Temperature — Resolution0.1°C/0.1°F
Temperature — Accuracy±0.5°C/±0.9°F
Temperature — Offset Calibration1 point, reading ±10℃
Other Specifications — Dissolved Oxygen Calibration1 or 2 points
Other Specifications — Temperature Compensation0~50°C, automatic
Other Specifications — Barometric Pressure Correction60.0-112.5kPa/450-850mmHg, manual
Other Specifications — Salinity Correction0.0-50.0g/L, manual
Other Specifications — Stability CriteriaLow or high
Other Specifications — Calibration Due Alarm1 to 31 days or off
Other Specifications — Hold FunctionManual or auto-endpoint
Other Specifications — Memory500 data sets
Other Specifications — Communication InterfaceUSB
Other Specifications — Connector6-pin nimi-DIN
Other Specifications — DisplayCustom LCD (125×100mm)
Other Specifications — Power RequirementsDC5V power adapter
Other Specifications — Sizes(W×D×H)210×188×60
Other Specifications — Shipping Size (W×D×H)(mm)300x250x200
Other Specifications — N.W./G.W. (kg)1.5/2
DO-B100T — Benchtop Dissolved Oxygen Meter, Touch-screen
DO — Range0-20.00 mg/L (ppm), 0-200.0 %
DO — Accuracy/Resolution± 0.30 mg/L; 0.01 or 0.1 mg/L
DO — ATC Range(0 - 50)℃ automatically
DO — Salinity Compensation0~45 ppt manual
DO — Barometric Compensation0~200 kPa automatically
mV (ORP Probe Optional) — Range-1, 999mV -+1, 999mV
mV (ORP Probe Optional) — Resolution± 0.1/1mV
mV (ORP Probe Optional) — Accuracy±0.03% FS ±1digit
Temperature — Range-10.0~135℃(14.0~275.0)℉
Temperature — Resolution/Accuracy0.1℃; ±0.2℃
Data Storage5000 groups
Data Output1. USB to Flash Disk
Data Output2. USB to PC
Data Output3. Wireless connection to printer (the printer is optional)
Power SupplyDC12V
Packing Including1. DO-B100T Meter
Packing Including2. DO01-2M Polarographic DO probe, cable length: 2m
Packing Including3. DOS-01 Membrane refill solution: 30mL, 1pc
Packing Including4. DOSC Sensor caps: 3pcs/group, 1pkg
Packing Including5. F01 Flexible probe holder: 1pc
Packing Including6. Magnetic stirrer: 1pc
Packing Including7. PC cable: 1pc
Packing Including8. A01 Power adaptor
Shipping Size (WxDxH)(mm)430x600x130
N.W. / G.W. (kg)2.1 / 3

Specification published by Scitek Global. Confirm the exact configuration on the written quotation before ordering.

Key features

What the range offers

  • High-resolution LCD display screen.
  • With built-in microprocessor chip, automatic calibration, automatic temperature compensation, data storage, parameter setup, etc.
  • Automatic calibration, self-diagnosis.
  • Fast response, high accuracy, stable reading display.
  • Calibration points: DO: 100% Oxygen or Zero oxygen calibration.
  • Each kit comes with a polarographic type DO probe and 3pcs replaceable sensor caps.
  • IP54 dustproof and spillproof.
  • The measurement accuracy of 0.5mg/L can meet most of the experimental needs. In addition, salinity and atmospheric pressure are compensated to eliminate measurement errors.
  • Dissolved oxygen meter's sensor is susceptible and accurate.
  • Dissolved oxygen meter is calibrated with zero oxygen solution and air-saturated water to ensure calibration reliability.

Next step

Tell us the measurement and the range.

We will confirm the right model, the price and the lead time.

Message on WhatsApp
Chat on WhatsApp