Home/Products/Scitek Global/Benchtop Conductivity Meter
Weighing & measurement
Benchtop Conductivity Meter
- Models
- CON-TSRB150; CON-TSRB151; CON-B100I; EC100B; CON-B12DW; EC200E; CON-B100T; CON-TB510; CON-TSRB950
- Conductivity — Range
- 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
- Conductivity — Resolution
- 0.001, 0.01, 0.1, 1
- Conductivity — Accuracy
- ±0.5% F.S.
- Conductivity — Calibration Points
- 1 to 3 points
Reliably measure conductivity, TDS, salinity, resistivity and temperature with this conductivity benchtop meter for advanced lab analysis.
Added to your inquiry list. It travels with your next quote request.
9 models
Product Description
Benchtop Conductivity Meter specification for every model we supply. Figures are the manufacturer’s published values.
| Specification | Value |
|---|---|
| CON-TSRB150 — Benchtop Conductivity/TDS/Salinity/Resistivity Meter | |
| Conductivity — Range | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
| Conductivity — Resolution | 0.001, 0.01, 0.1, 1 |
| Conductivity — Accuracy | ±0.5% F.S. |
| Conductivity — Calibration Points | 1 to 3 points |
| Conductivity — Calibration Solutions | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| TDS — Range | 0~10.00, 100.0, 1000mg/L, 10.00, 200.0g/L |
| TDS — Resolution | 0.01, 0.1, 1 |
| TDS — Accuracy | ±1% F.S. |
| TDS — TDS Factor | 0.1-1.0(default 0.5) |
| Salinity — Range | 0.00~80.00ppt, 0.00~42.00psu, 0.00~8.00% |
| Salinity — Resolution | 0.01,0.1,1 |
| Salinity — Accuracy | ±1% F.S. |
| Resistivity — Range | 0.00~30.00MΩ |
| Resistivity — Resolution | 0.01,0.1,1 |
| Resistivity — Accuracy | ±1% F.S. |
| Conductivity Ash — Range | 0-100% |
| Conductivity Ash — Resolution | 0.01,0.1,1 |
| Conductivity Ash — Accuracy | ±1%F.S. |
| Conductivity Ash — Measurement Modes | Refined sugar or raw sugar |
| Temperature — Range | 0-105°C/32-221°F |
| Temperature — Resolution | 0.1°C/0.1°F |
| Temperature — Accuracy | ±0.5°C/±0.9°F |
| Temperature — Offset Calibration | 1 point, reading ±10°C |
| Other Specifications — Temperature Compensation | 0~100°C manual or automatic |
| Other Specifications — Temperature Coefficient | Linear (0.0~10.0%/°C), non-linear, pure water |
| Other Specifications — Reference Temperature | 20/25°C |
| Other Specifications — Cell Constant | 2-pole electrodes (K=0.1, 1, 10) or 4-pole electrode |
| Other Specifications — Stability Criteria | Standard or high-accuracy |
| Other Specifications — Calibration Due Alarm | 1 to 31 days or off |
| Other Specifications — Interval Readings | 10, 30, 60 seconds, 10, 30 minutes or off |
| CON-TSRB151 — Benchtop Conductivity/TDS/Salinity/Resistivity Meter | |
| Conductivity — Range | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
| Conductivity — Resolution | 0.001, 0.01, 0.1, 1 |
| Conductivity — Accuracy | ±0.5% F.S. |
| Conductivity — Calibration Points | 1 to 3 points |
| Conductivity — Calibration Solutions | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| TDS — Range | 0~10.00, 100.0, 1000mg/L, 10.00, 200.0g/L |
| TDS — Resolution | 0.01, 0.1, 1 |
| TDS — Accuracy | ±1% F.S. |
| TDS — TDS Factor | 0.1-1.0(default 0.5) |
| Salinity — Range | 0.00~80.00ppt, 0.00~42.00psu, 0.00~8.00% |
| Salinity — Resolution | 0.01,0.1,1 |
| Salinity — Accuracy | ±1% F.S. |
| Resistivity — Range | 0.00~30.00MΩ |
| Resistivity — Resolution | 0.01,0.1,1 |
| Resistivity — Accuracy | ±1% F.S. |
| Conductivity Ash — Range | _ |
| Conductivity Ash — Resolution | _ |
| Conductivity Ash — Accuracy | _ |
| Conductivity Ash — Measurement Modes | _ |
| Temperature — Range | 0-105°C/32-221°F |
| Temperature — Resolution | 0.1°C/0.1°F |
| Temperature — Accuracy | ±0.5°C/±0.9°F |
| Temperature — Offset Calibration | 1 point, reading ±10°C |
| Other Specifications — Temperature Compensation | 0~100°C manual or automatic |
| Other Specifications — Temperature Coefficient | Linear (0.0~10.0%/°C), non-linear, pure water |
| Other Specifications — Reference Temperature | 20/25°C |
| Other Specifications — Cell Constant | 2-pole electrodes (K=0.1, 1, 10) or 4-pole electrode |
| Other Specifications — Stability Criteria | Standard or high-accuracy |
| Other Specifications — Calibration Due Alarm | 1 to 31 days or off |
| Other Specifications — Interval Readings | 10, 30, 60 seconds, 10, 30 minutes or off |
| CON-B100I — Benchtop Conductivity Meter, Automatic Calibration | |
| Cond. — Range | 0~200.0mS/cm, auto divided by range of: 0~19.999µS/cm 20.0~199.9µS/cm 200~1999µS/cm 2.00~19.99mS/cm 20.00~199.9mS/cm TDS: 0 -100.0g/L Resistivity: 5.00Ω·cm-100.0MΩ·cm Salinity: 0-100.0 ppt |
| Cond. — Resolution | 0.001 |
| Cond. — Accuracy | ±1.0 % FS±1digit |
| Temperature — Range | -9.9℃~130℃ (14.1~266)℉ |
| Temperature — Resolution/ Accuracy | 0.1℃; ±0.2℃ |
| Data Storage | 450groups |
| Data Output | 1. USB to Flash Disk |
| Data Output | 2. Wireless connection to printer (the printer is optional) |
| Power Supply | DC12V |
| Packing Including | 1. CON-B100I Meter |
| Packing Including | 2. CON201TG Glass Cond probe |
| Packing Including | 3. Standard Cond solution: 50mL: 84µS/1413µS/12.88mS/cm, one for each |
| Packing Including | 4. F01 Flexible probe holder: 1pc |
| Packing Including | 5. Power adaptor: 1pc |
| Packing Including | 6. A01 Power adaptor |
| Shipping Size (WxDxH)(mm) | 330x540x130 |
| N.W. / G.W. (kg) | 1.7 / 2.2 |
| EC100B — Benchtop Conductivity Meter, 1 Calibration Point | |
| Parameters | EC |
| Conductivity — Range | 0.00 µS/cm to 100 mS/cm |
| Conductivity — Resolution | 0.01 µS/cm minimum, various with range selection |
| Conductivity — Accuracy | ±1.5% FS |
| Conductivity — Reference Temperature | 25 ºC |
| Measurement — Reading Mode | Continuous |
| Measurement — Reading Prompts | Reading, Stable, Locked |
| Measurement — Temp. Compensation | MTC |
| Inputs — Conductivity Probe | 5-pin aviation connector |
| Display Options — Backlight | Yes |
| Display Options — Auto Shutdown | 300, 600, 1200, 1800, 3600 sec., off |
| Display Options — IP Rating | IP54 |
| General — Power | AC Adapter, 100-240V AC input, DC9V output |
| General — External Size(W×D×H) | 200×160×63 |
| General — Shipping Size (W×D×H)(mm) | 300×290×140 |
| General — G.W. (kg) | 1.5 |
| Includes — Accessories | DJS-1VC EC electrode 1413µS/cm EC standard solution, 50ml, 1 vial Electrode Stand |
| CON-B12DW — Benchtop Conductivity Meter, 3 Calibration Points | |
| Range | 0.01 to 20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Accuracy | ±1% F.S. |
| Calibration Points | 1 to 3 points |
| Calibration Solutions | 10µS, 84µS, 1413µS, 12.88mS, 111.8mS |
| Range | 0 to 105℃/32 to 221°F |
| Resolution | 0.1℃/0.1°F |
| Accuracy | ±1℃/±1.8°F |
| Offset Calibration | 1 point |
| Calibration Range | Reading ±10℃ |
| Temperature Compensation | 0 to 100℃/32 to 212°F, manual or automatic |
| Temperature Coefficient | Linear (0.0 to 10.0%/℃) |
| Reference Temperature | 25℃ |
| Cell Constant | K=0.1, 1, 10 or custom |
| Hold Function | Manual or auto-endpoint |
| Connector | 6-pin mini-DIN, 3.5mm jack socket |
| Display | Custom LCD (120x60mm) |
| Power | DC9V, using AC adapter, 220V/50Hz |
| Sizes(W×D×H) | 210x205x75 |
| Shipping Size (W×D×H)(mm) | 300x250x200 |
| N.W./G.W. (kg) | 1.5/2 |
| EC200E — Benchtop Conductivity Meter EC200E | |
| Parameters | EC/Temp.(TDS) |
| Conductivity — Range | 0.00 µS/cm to 200 mS/cm |
| Conductivity — Resolution | 0.01 µS/cm minimum, various with range selection |
| Conductivity — Accuracy | ±1.0% FS |
| Conductivity — Reference Temperature | 25 ºC |
| Conductivity — Calibration Points | Up to 1 |
| Conductivity — Standard Recognition | 84µS/cm, 1413µS/cm, 12.88mS/cm |
| TDS — Range | 0.00mg/L~100g/L |
| TDS — Resolution | 0.01mg/L minimum, various with range selection |
| TDS — Accuracy | ±1.0% FS |
| Temperature — Range | -5.0 to 110 ℃ |
| Temperature — Unit | ºC |
| Temperature — Resolution | 0.1 |
| Temperature — Accuracy | ±0.2 |
| Measurement — Reading Mode | Auto Read, Continuous |
| Measurement — Reading Prompts | Reading, Stable, Locked |
| Measurement — Temp. Compensation | ATC, MTC |
| Data Management — Data Storage | 50 results each |
| Inputs — Conductivity with Temp. Probe | 5-pin aviation connector |
| Display Options — Backlight | Yes |
| Display Options — Auto Shutdown | 300, 600, 1200, 1800, 3600 sec., off |
| Display Options — IP Rating | IP54 |
| General — Power | AC Adapter, 100-240V AC input, DC9V output |
| General — External Sizes (W×D×H)(mm) | 242×195×68 |
| General — Shipping Size (W×D×H)(mm) | 350×280×220 |
| General — G.W. (kg) | 2.5 |
| Includes — Accessories | DJS-1VTC EC electrode 1413µS/cm EC standard solution, 50ml, 1 vial REX-5 electrode stand |
| CON-B100T — Benchtop Conductivity Meter, Touch-screen | |
| Cond. — Range | 0~2000.0mS/cm, auto divided by range of: 0~19.999µS/cm 20.0~199.9µS/cm 200~1999µS/cm 2.00~19.99mS/cm 20.00~199.9mS/cm 200.0~2000mS/cm(K=10) the match test: 0-200.0mS/cm |
| Cond. — Resolution | 0.001 |
| Cond. — Accuracy | ±0.5 % FS±1digit |
| Temperature — Range | -10.0~135℃(14.0~275.0)℉ |
| Temperature — Resolution/ Accuracy | 0.1℃; ±0.2℃ |
| Data Storage | 5000 groups |
| Data Output | 1. USB to Flash Disk |
| Data Output | 2. USB to PC |
| Data Output | 3. Wireless connection to printer (the printer is optional) |
| Power Supply | DC12V |
| Packing Including | 1. CON-B100T Meter |
| Packing Including | 2. CON201TG Glass ATC Cond probe, (K=1) |
| Packing Including | 3. Standard Cond solution: 50mL: 84µS/1413µS/12.88mS/cm, one for each |
| Packing Including | 4. F01 Flexible probe holder: 1pc |
| Packing Including | 5. Magnetic stirrer: 1pc |
| Packing Including | 6. PC cable: 1pc |
| Packing Including | 7. A01 Power adaptor |
| Shipping Size (WxDxH)(mm) | 430x600x130 |
| N.W. / G.W. (kg) | 2.2 / 3 |
| CON-TB510 — Benchtop Conductivity/TDS/Salinity / Resistivity Meter | |
| Conductivity — Range | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
| Conductivity — Resolution | 0.001, 0.01, 0.1, 1 |
| Conductivity — Accuracy | ±1% F.S. |
| Conductivity — Calibration Points | 1 to 3 points |
| Conductivity — Calibration Solutions | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| TDS — Range | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
| TDS — Resolution | 0.01, 0.1, 1 |
| TDS — Accuracy | ±1%F.S. |
| TDS — TDS Factor | 0.1~1.0 (default 0.5) |
| Salinity — Range | — |
| Salinity — Resolution | — |
| Salinity — Accuracy | — |
| Resistivity — Range | — |
| Resistivity — Resolution | — |
| Resistivity — Accuracy | — |
| Temperature — Range | 0~105°C/32~221°F |
| Temperature — Resolution | 0.1°C/0.1°F |
| Temperature — Accuracy | ±1°C/±1.8°F |
| Temperature — Offset Calibration | 1 point, reading ±10°C |
| Other Specifications — Temperature Compensation | 0~100°C, manual or automatic |
| Other Specifications — Temperature Coefficient | Linear (0.0~10.0%/°C) |
| Other Specifications — Reference Temperature | 25°℃ |
| Other Specifications — Cell Constant | K=0.1,1,10 or custom |
| Other Specifications — Stability Criteria | 一 |
| Other Specifications — Calibration Due Alarm | 一 |
| Other Specifications — Calibration Factor Display | 一 |
| Other Specifications — Hold Function | Manual or auto-endpoint |
| Other Specifications — Memory | 一 |
| Other Specifications — Communication Interface | 一 |
| Other Specifications — Connector | 6-pin mini-DIN, 3.5mm jack socket |
| CON-TSRB950 — Benchtop Conductivity/TDS/Salinity / Resistivity Meter | |
| Conductivity — Range | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
| Conductivity — Resolution | 0.001, 0.01, 0.1, 1 |
| Conductivity — Accuracy | ±0.5% F.S. |
| Conductivity — Calibration Points | 1 to 5 points |
| Conductivity — Calibration Solutions | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| TDS — Range | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
| TDS — Resolution | 0.01, 0.1, 1 |
| TDS — Accuracy | ±1%F.S. |
| TDS — TDS Factor | 0.1~1.0 (default 0.5) |
| Salinity — Range | 0.00~42.00psu, 0.00~80.00ppt |
| Salinity — Resolution | 0.01 |
| Salinity — Accuracy | ±1% F.S. |
| Resistivity — Range | 0.00~20.00MΩ |
| Resistivity — Resolution | 0.01 |
| Resistivity — Accuracy | ±1% F.S. |
| Temperature — Range | 0~105°C/32~221°F |
| Temperature — Resolution | 0.1°C/0.1°F |
| Temperature — Accuracy | ±0.5°C/±0.9°F |
| Temperature — Offset Calibration | 1 point, reading ±10°C |
| Other Specifications — Temperature Compensation | 0~100°C, manual or automatic |
| Other Specifications — Temperature Coefficient | Linear (0.0~10.0%/°C), pure water |
| Other Specifications — Reference Temperature | 20/25°C |
| Other Specifications — Cell Constant | K=0.1,1,10 or custom |
| Other Specifications — Stability Criteria | Low or high |
| Other Specifications — Calibration Due Alarm | 1 to 31 days or off |
| Other Specifications — Calibration Factor Display | Yes |
| Other Specifications — Hold Function | Manual or auto-endpoint |
| Other Specifications — Memory | 500 data sets |
| Other Specifications — Communication Interface | uSB |
| Other Specifications — Connector | 6-pin mini-DIN, 3.5mm jack socket |
Specification published by Scitek Global. Confirm the exact configuration on the written quotation before ordering.
Key features
What the range offers
- Highly accurate laboratory conductivity meter with 7-inch TFT display.
- 1 to 3 point calibration, automatic recognition of conductivity standards.
- Selectable electrode constants (K=0.1/1/10), reference temperature (20/25°C), TDS conversion factor, linear/non-linear/pure water compensation, percentage of ratio/seawater/utility salinity measurement modes.
- Automatic temperature compensation, corrects conductivity measurements and converts readings to reference temperature.
- Automatic endpoint lock, retains stable readings for easy viewing and recording.
- High-res LCD display screen.
- With built-in microprocessor chip, automatic calibration, automatic temperature compensation, data storage, parameter setup, etc.
- Automatic calibration, self-diagnosis, automatically recognizing standard buffer solutions, conductivity calibration point: 1pt.
- Fast response, high accuracy, stable reading display.
- The kit comes with an ATC plastic cond. probe.
Next step
Tell us the measurement and the range.
We will confirm the right model, the price and the lead time.