Benchtop Touch Screen Conductivity Meter
- Models
- LOCM-A10; LOCM-A11; LOCM-B10
- Resistivity Measuring Range
- (0 to 100) MΩ·cm
- TDS Measuring Range
- (0 to 100) g/L
- Salinity Measuring Range
- (0 to 100) ppt
- Resolution
- 0.01/0.1/1 μS/cm, 0.01/0.1/1 mS/cm, 0.1/1/10 μS/cm
Labtron
Added to your inquiry list. It travels with your next quote request.
3 models
Product Description
Benchtop Touch Screen Conductivity Meter specification for every model we supply. Figures are the manufacturer’s published values.
| Specification | Value |
|---|---|
| LOCM-A10 — Touchscreen Conductivity Meter | |
| Conductivity Measuring Range | (0.00 to 20.00) μS/cm, (20.0 to 200.0) μS/cm, (200 to 2000) μS/cm, (2.00 to 20.00) mS/cm, (20.0 to 200.0) mS/cm |
| Resistivity Measuring Range | (0 to 100) MΩ·cm |
| TDS Measuring Range | (0 to 100) g/L |
| Salinity Measuring Range | (0 to 100) ppt |
| Resolution | 0.01/0.1/1 μS/cm, 0.01/0.1/1 mS/cm, 0.1/1/10 μS/cm |
| Accuracy | Electrode: ±1.0% FS, Instrument: ±1.50% FS |
| Temperature Compensation Range | (0 to 100) °C (Automatic) |
| Electrode Constant | 0.1/1/10 cm^−1 |
| Temperature Measuring Range | -10°C to 110°C |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | 5 to 80°C ±0.5°C, Others ±1.0°C |
| Data Storage Capacity | 1000 sets |
| Storage Content | Measurement series number, measuring value, temperature, ATC or MTC status, date, and time |
| Ambient Temperature | 5 to 35°C |
| Ambient Humidity | Upto 80% |
| Communications | Bluetooth, USB |
| IP Rating | IP54 |
| Power Supply | DC12V 1A |
| Dimensions | 240 × 170 × 70 mm |
| Weight | 0.8 kg |
| LOCM-A11 — Touchscreen Conductivity Meter | |
| Conductivity Measuring Range | (0.000 to 2000)μS/cm (0.000 to 1.999)μS/cm, (2.000 to 19.999)μS/cm (20.000 to 199.999)μS/cm, (200.000 to 1999.999)μS/cm (2.000 to 19.999)mS/cm, (20.000 to 199.999)mS/cm (200.000 to 2000.000)mS/cm (K=10) TDS: 0.00 mg/L to 1000g/L Salinity: (0 to 80)ppt Resistivity: (0 to 100) MΩ·cm |
| Conductivity Resolution | 0.001/0.01/0.1/1μS/cm, 0.001/0.01/0.1/1mS/cm |
| Conductivity Accuracy | ±0.5% |
| Conductivity Temperature Compensation | 0 to 100℃, auto |
| Conductivity Electrode Constant | 0.1/1/10 cm -1 |
| Conductivity Reference Temperature | 25℃, 20℃, 18℃ |
| Temperature Measuring Range | -30.0 to 130℃ |
| Temperature Resolution | 0.1℃ |
| Temperature Accuracy | ±0.1℃ (0 to 100.0℃), ±0.3℃ (up to 0.0℃ or at least 100.0℃) |
| Data Storage | 2000 sets |
| Power | DC 12V/1A |
| Output | USB |
| Ambient Temperature | 5 to 40℃ |
| Ambient Humidity | Up to 85% |
| IP Grade | IP54 |
| Dimensions | 215 × 170 × 37 mm |
| Net Weight | 600 g |
| Packaging Dimensions | 470 × 430 × 72 mm |
| Gross Weight | 3 Kg |
| LOCM-B10 — Touchscreen Conductivity Meter | |
| Conductivity Measuring Range | (0.00 to 20.00)μS/cm, (20.0 to 200.0)μS/cm (200 to 2000)μS/cm, (2.00 to 20.00)mS/cm (20.0 to 200.0)mS/cm (200 to 2000)mS/cm (K=10) TDS: 0 to 100 g/L Salinity: 0 to 100 ppt Resistivity: 0 to 100 MΩ·cm |
| Conductivity Resolution | 0.01/0.1/1μS/cm; 0.01/0.1/1mS/cm |
| Conductivity Accuracy | Electrode: ± 0.5% F S, Meter: ± 0.80% F S |
| Conductivity Temperature Compensation | 0 to 50℃, auto |
| Conductivity Electrode Constant | 0.1/0.5/1/5/10/100 cm -1 |
| Conductivity Reference Temperature | 25℃, 20℃, 18℃ |
| Temperature Measuring Range | -10 to 110℃ |
| Temperature Resolution | 0.1℃ |
| Temperature Accuracy | 5 to 60℃: ± 0.4℃ Others: ± 0.8℃ |
| Display | 7-inch colored capacitive touch screen |
| Data Storage | 1000 sets |
| Power | 12V/1A |
| Output | USB |
| Ambient Temperature | 15 to 30 ℃ |
| Ambient Humidity | Up to 85% |
| IP Grade | IP54 |
| Dimensions | 215 × 170 × 37 mm |
| Packaging Dimension | 470 x 430 x 72 mm |
| Net Weight | 600 g |
| Gross Weight | 3 Kg |
Specification published by Labtron. Confirm the exact configuration on the written quotation before ordering.
Key features
What the range offers
- Adjustable screen brightness
- Resolution setting options
- Real-time clock display
- 1000-set memory capacity
- Auto solution recognition
- One-point electrode calibration
- TDS and salinity conversion
- Large color touchscreen
Applications
Where it is used
- Our Touchscreen Conductivity Meter LOCM-A10 is suitable for measuring water conductivity, TDS, resistivity, and salinity in a wide range of solutions. It is commonly used in lab research, water quality monitoring, and educational applications.
- Labtron’s Touchscreen Conductivity Meter LOCM-A11 is widely used for water quality analysis, mainly in drinking water treatment plants, industrial, and wastewater treatment plants. It is also used for laboratory purposes, environmental monitoring, food and beverage industry, and more.
- Our Touchscreen Conductivity Meter LOCM-B10 features a compact design and a waterproof build, making it suitable for both laboratory and field applications. It is widely used in environmental monitoring, drinking water and wastewater treatment, educational and research institutions, the pharmaceutical industry, agriculture, and the food and beverage industry.
Next step
Tell us the capacity and the duty.
We will confirm the right model, the price and the lead time.