Authorized distributor · Karachi

Home/Products/Labtron/Benchtop pH Meter

Labtron Weighing & measurement

Benchtop pH Meter

Models
LBPM-A11; LBPM-A20; LBPM-B10; LBPM-B11; LBPM-C11
pH measurement range
0.00 to 14.00 pH
pH accuracy
± 0.01 pH
pH resolution
0.01 pH
Calibration points
2 points

We are manufacturers of Benchtop pH Meter LBPM-A11 featuring automatic 2 point calibration for identifying pH buffer and a smart backlit LCD display for ease of monitoring.

Labtron 5 models

Product Description

Benchtop pH Meter specification for every model we supply. Figures are the manufacturer’s published values.

Benchtop pH Meter specification, by model, as published by Labtron
SpecificationValue
LBPM-A11 — Benchtop pH Meter
pH measurement range0.00 to 14.00 pH
pH accuracy± 0.01 pH
pH resolution0.01 pH
Calibration points2 points
Calibration solutionsUSA (pH 4.0/7.00/10.01)
Temperature compensation0 to 100°C
Compensation modeManual or automatic
mV range-1999 to 1999 mV
mV accuracy±1mV
mV resolution1 mV
Temperature range0 to 100°C, 32 to 212°F
Temperature accuracy±1°C
Temperature resolution1°C
ConnectorBNC
DisplayLCD
Dimension (L*W*H)210×205×65 mm
PowerDC9V, Ac adapter, AC220V /50Hz
Net Weight1.5 kg
Gross Weight3 kg
LBPM-A20 — Benchtop pH Meter
pH measurement range-1.00 to 15.00 pH
pH accuracy± 0.01 pH
pH resolution0.01 pH
Calibration points1-3 points
Buffer SetsUSA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)
Temperature compensation0 to 100°C, 32 to 212°F
Compensation modeManual or automatic
mV range-1000 to 1000 mV
mV accuracy±1mV
mV resolution1 mV
Temperature range0 to 105°C, 32 to 221°F
Temperature accuracy±1°C
Temperature resolution0.1°C
Hold functionManual or automatic endpoint detection
Power offManual or automatic (180 minutes after last key is pressed)
Reset functionYes
ConnectorBNC
DisplayLCD
Dimension (L*W*H)210×205×75 mm
Weight1.5 kg
PowerDC9V, AC adapter, AC220V/50Hz
LBPM-B10 — Benchtop pH Meter
pH measurement range-2.000 to 20.000 pH
pH accuracy± 0.002 pH
Calibration points1-5 points
Calibration solutionsUSA, NIST, DIN or user defined
ORP measurement range-1999.9 to 1999.9 mV
ORP accuracy±0.2 mV
ORP calibration points1 point
ORP calibration range±200 mV
ORP calibration solutionsmV & relative mV
Temperature compensation0 to 100°C, 32 to 212°F
Compensation modeManual or automatic
Stability conditionsLow or high
Calibration due0 to 31 days
memoryStores up to 500 data sets
OutputUSB communication interface
ConnectorBNC
DisplayLCD
Dimension (L*W*H)210×188×60 mm
Weight1 kg
PowerDC5V using AC adapter, AC220V /50 Hz
Gross Weight1.8 Kg
LBPM-B11 — Benchtop pH Meter
Temperature compensation0 to 100°C, 32°F to 212°FManual or Automatic
Hold functionManual or automatic endpoint detection
Stability criteriaStandard or High-accuracy
Interval readings10, 30, 60 seconds, 10, 30 minutes or Off
Calibration due alarm1 to 31 days
MemoryStores up to 1000 data sets
OutputUSB communication interface
Display7 inch TFT LCD
Accuracy± 0.002 pH
Resolution0.001, 0.01 pH
Calibration points1 to 5 points
LBPM-C11 — Benchtop pH Meter
pH Measuring Range-2.0 to 19.99 pH
pH AccuracyMeter: ±0.01 pH; Complete Kit: ±0.02 pH
pH Resolution0.1 / 0.01 pH
Calibration Points1, 2, 3 points
ORP Measuring Range±1999.9 mV
ORP Resolution0.1 mV
ORP Accuracy±0.03% FS
Temperature Range0 °C to 100 °C
Temperature Accuracy±0.4 °C (5 °C to 60 °C)
Temperature Resolution0.1 °C
Temperature CompensationAuto or Manual
Buffer StandardsEurope, USA, NIST
Input Current≤2×10⁻¹² A
Input Impedance≥1×10¹² Ω
Stability±0.02 pH / 3 h
Data Storage1000 sets
Display6.5 inch LCD
OutputUSB
Ambient Temperature5 °C to 35 °C
Ambient HumidityUpto 85%
IP RatingIP54
Power Supply12V/1A
Dimensions215 × 170 × 37 mm
Weight0.6 kg

Specification published by Labtron. Confirm the exact configuration on the written quotation before ordering.

Key features

What the range offers

  • Equipped with white backlit LCD display
  • pH measurement range 0.0 to 14.00 pH
  • 2 points calibration to automatically identify pH buffer
  • Automatic electrode slope display, helps the operator when to replace the sensor
  • Automatic temperature compensation for accurate measured value over the entire range
  • Universal BNC connector
  • Built-in solution holder
  • pH measurement range: -1.00 to 15.00 pH

Applications

Where it is used

  • The benchtop pH meter can be used for daily measurement of pH & temperature at schools, colleges & research laboratories & water testing plants.
  • Benchtop pH meter is used for research education purpose, quality testing in water and waste water management plants, food and beverage industry & other liquids & solvents.
  • The benchtop pH meter can be used for daily measurement of pH, ORP & temperature at schools, colleges & research laboratories & water testing plants.
  • Used for daily measurement of pH, ORP and temperature at schools, colleges and research laboratories and water testing plants
  • Our Benchtop pH Meter LBPM-C11 is widely used in environmental testing and industrial labs. It is suitable for quality analysis in chemical production, wastewater treatment, and agriculture labs.

Next step

Tell us the capacity and the duty.

We will confirm the right model, the price and the lead time.

Message on WhatsApp
Chat on WhatsApp