Authorized distributor · Karachi

Home/Products/Labtron/Automatic Refractometer

Labtron Spectroscopy

Automatic Refractometer

Models
LAR-A10; LAR-A11; LAR-A12; LAR-A13; LAR-A14
Measurement Range
1.30000 to 1.70000 (nD)
Resolution
0.0001 (nD)
Precision
±0.0002
Temperature Control Range
Room temperature

Labtron is a trusted supplier of the Automatic Refractometer. The LAR-A10 model features a 1.30000 to 1.70000 (nD) range, Peltier control, and a 7-inch touchscreen for accurate lab analysis.

Labtron 5 models

Product Description

Automatic Refractometer specification for every model we supply. Figures are the manufacturer’s published values.

Automatic Refractometer specification, by model, as published by Labtron
SpecificationValue
LAR-A10 — Automatic Refractometer
Measurement Range1.30000 to 1.70000 (nD)
Resolution0.0001 (nD)
Precision±0.0002
Temperature Control RangeRoom temperature
Temperature Stability±0.03°C
Brix Range0 to 100%
Brix Accuracy±0.1%
Test ModeRefractive index / sugar content or customized
Temperature Control MethodNo
Light SourceLED
Wavelength589 nm
PrismSapphire
Sample CellStainless steel
Detection MethodHigh-resolution linear CCD
Display7-inch TFT color touch screen
Data Storage32G
OutputUSB, RS232, RJ45, SD card
User ManagementYes, four-level
Compliance21 CFR Part 11, CE Certified
Power Supply220V / 50Hz
Dimension440 × 400 × 340 mm
Weight7.15 kg
LAR-A11 — Automatic Refractometer
Measurement Range1.30000 to 1.70000 (nD)
Resolution0.0001 (nD)
Precision±0.0002
Temperature Control Range5°C to 65°C
Temperature Stability±0.03°C
Brix Range0 to 100%
Brix Accuracy±0.1%
Test ModeRefractive index / sugar content or customized
Temperature Control MethodBuilt-in Peltier
Light SourceLED
Wavelength589 nm
PrismSapphire
Sample CellStainless steel
Detection MethodHigh-resolution linear CCD
Display7-inch TFT color touch screen
Data Storage32G
OutputUSB, RS232, RJ45, SD card
User ManagementYes, four-level
Compliance21 CFR Part 11, CE Certified
Power Supply220V / 50Hz
Dimension440 × 400 × 340 mm
Weight7.15 kg
LAR-A12 — Automatic Refractometer
Measurement Range1.30000 to 1.70000 (nD)
Resolution0.0001 (nD)
Precision±0.0003
Temperature Control Range5°C to 65°C
Temperature Stability±0.02°C
Brix Range0 to 100%
Brix Accuracy±0.05%
Test ModeRefractive index / sugar content / honey moisture / salinity or customized
Temperature Control MethodBuilt-in Peltier
Light SourceLED
Wavelength589 nm
PrismSapphire
Sample CellHastelloy
Detection MethodHigh-resolution linear CCD
Display7-inch TFT color touch screen
Data Storage32G
OutputUSB, RS232, RJ45, SD card, U Disk
User ManagementYes, four-level
Compliance21 CFR Part 11, CE Certified
Power Supply220V / 50Hz
Dimension440 × 400 × 340 mm
Weight7.15 kg
LAR-A13 — Automatic Refractometer
Measurement Range1.30000 to 1.70000 (nD)
Resolution0.0001 (nD)
Precision±0.0002
Temperature Control Range5°C to 90°C
Temperature Stability±0.01°C
Brix Range0 to 100%
Brix Accuracy±0.01%
Test ModeRefractive index / sugar content / honey moisture / salinity or customized
Temperature Control MethodBuilt-in Peltier
Light SourceLED
Wavelength589 nm
PrismSapphire
Sample CellHastelloy
Detection MethodHigh-resolution linear CCD
Display7-inch TFT color touch screen
Data Storage64G
OutputUSB, RS232, RJ45, SD card, U Disk
User ManagementYes, four-level
Compliance21 CFR Part 11, CE Certified
Power Supply220V / 50Hz
Dimension440 × 400 × 340 mm
Net Weight5 kg
Gross Weight7.15 kg
LAR-A14 — Automatic Refractometer
Measurement Range1.3000 to 1.7000 (nD)
Resolution0.0001
Precision±0.0001
Accuracy±0.0001
Correction PointMulti-point fitting system
Brix Range0 to100%
Brix Resolution±0.1%
Temperature Control ModePeltier control temperature.
Temperature Controlled MethodNo
Temperature Range0 to100°C
Temperature Control Range5℃ to 70℃
Temperature Accuracy±0.02℃
Temperature Control Stability±0.03℃
Wavelength589nm
PrismSapphire grade
Sample CellStainless steel
Detection ModeLinear CCD
Output ModeUSB, RS232, RJ45, SD card, U disk.
Data Storage32 G
User ManagementFour-level
Data Saving FormatPDF, Excel
Audit TrackingYes
Dimensions300 mm ×380 mm ×300 mm

Specification published by Labtron. Confirm the exact configuration on the written quotation before ordering.

Key features

What the range offers

  • High-resolution linear CCD detection
  • 7-inch TFT touch screen interface
  • Compact and lightweight design
  • LED cold light source
  • Four-level user authority management
  • Supports multiple data export formats
  • Built-in Peltier temperature control
  • Stainless steel sample chamber

Applications

Where it is used

  • Our Automatic Refractometer LAR-A10 is widely used in the food industry for sugar content analysis and quality control. It is also applied in pharmaceutical research to measure sample purity and solid content.
  • Our Automatic Refractometer LAR-A11 is designed for temperature-controlled refractive index testing in pharmaceuticals, cosmetics, and dairy industries. It is commonly used in cosmetic labs, pharmaceutical R&D, and dairy processing.
  • Our Automatic Refractometer LAR-A12 is ideal for industries requiring precise refractive index and Brix analysis across a wide range of liquids. Its ability to test honey moisture and salinity makes it valuable for food quality control and production monitoring.
  • Our Automatic Refractometer LAR-A13 is suitable for high-precision laboratory research and industrial analysis. With an extended temperature range up to 90°C, it is ideal for petrochemical and polymer industries requiring thermal stability in testing.
  • Automatic Refractometer LAR-A14 automatically measures the refractive index of liquids by detecting the critical angle of light. It is applied in petroleum, grease, food industry, sugar and chemical industries for measuring the concentration, purity and quality of liquid samples.

Next step

Tell us the capacity and the duty.

We will confirm the right model, the price and the lead time.

Message on WhatsApp
Chat on WhatsApp