Heating, cooling & storage
Test Chamber
- Models
- LZ-MSC-A102; LZ-PGC-A100; LZ-SSC-A100; LZ-THC-A100; LZ-UVC-A110
- Chamber Volume
- 500L
- Temperature Control Range
- 0 to 65°C without illumination, 10 to 50°C with illumination
- Temperature Stability
- ±0.5 °C
- Temperature Uniformity
- ±2 °C
Stability, temperature-humidity and environmental chambers for shelf-life studies.
Added to your inquiry list. It travels with your next quote request.
5 models
Product Description
Test Chamber specification for every model we supply. Figures are the manufacturer’s published values.
| Specification | Value |
|---|---|
| LZ-MSC-A102 — Medical Stability Test Chamber | |
| Chamber Volume | 500L |
| Temperature Control Range | 0 to 65°C without illumination, 10 to 50°C with illumination |
| Temperature Stability | ±0.5 °C |
| Temperature Uniformity | ±2 °C |
| Humidity Range | 35 to 95%RH |
| Humidity Stability | ±3%RH |
| Illumination | 0 to 6000LX adjustable |
| Refrigerant | R134a |
| Illumination Difference | ≤±500LX |
| Cooling System/Cooling Mode | Two sets of imported compressor work rotationally |
| Controller | Programmable (touch screen) |
| Sensor | Temp: Pt100, Humidity: capacitance sensor |
| Ambient Temperature | RT+5 to 30°C |
| Shelves | 4 pcs |
| Safety Device | Compressor overheating and overpressure protection, Fan overheating protection, Over temperature protection, Overload protection, Water protections |
| Internal Dimension(W×D×H) | 670×725×1020 mm |
| External Dimension(W×D×H) | 850×1100×1930 mm |
| Power Consumption | 3750 W |
| Power supply | AC220V 50Hz |
| LZ-PGC-A100 — Plant Growth Chamber | |
| Volume | 300L |
| Temperature Range | Lights Off: 4°C to 50°C Light ON: 10°C to 50°C |
| Temperature Stability | ±1°C |
| Temperature Uniformity | ±2°C |
| Ambient Temperature | +5 ~ 30°C |
| Temperature Controller | Microprocessor |
| Illumination | 3 sides illumination, 0-20000LX, Six grade adjustable |
| Shelves | 3 |
| Material | Stainless steel interior |
| Working Time | No less than 180h |
| Power | 1450 W |
| Power Supply | 220V 50Hz |
| Interior Dimensions | 520 x 550 x 1140 mm |
| Exterior Dimensions | 830 x 850 x 1850 mm |
| Packing Dimensions | 950 x 930 x 210 mm |
| Gross Weight | 290 kg |
| LZ-SSC-A100 — Salt Spray Test Chamber | |
| Spray type | Continuous / Periodic |
| Temperature range | 35℃ to 55℃ |
| Temperature fluctuation | ≤±0.5℃ |
| Temperature uniformity | 2℃ |
| Humidity range | 95 to 98% RH |
| Air saturator | RT+5℃ to 55℃ |
| Spray deposition | 1 to 2 ml/cm 2 h |
| Dimension | 450 × 600 × 400 mm |
| External dimension | 800 × 108 × 108 mm |
| Power consumption | 1.3 kW |
| Power supply | AC 220 V 50 Hz |
| Gross weight | 120 kg |
| LZ-THC-A100 — Temperature and Humidity Test Chamber | |
| Capacity | 80 L |
| Temperature Range | 5 to 80°C |
| Display Resolution | 0.1℃ |
| Temperature Stability | High ±0.5℃ Low ±1℃ |
| Temperature Uniformity | ±2℃ |
| Humidity Range | 40 to 85 % |
| Humidity Accuracy | ±3 % RH |
| Ambient Temperature | +5 to 35℃ |
| Shelves | 2 pcs |
| Internal Dimension | 400 × 400 × 500 mm |
| External Dimension | 550 × 790 × 1080 mm |
| Power Consumption | 2000 W |
| Power supply | 220 V, 50 Hz |
| Net weight | 122 kg |
| Gross weight | 165 kg |
| LZ-UVC-A110 — UV Chamber | |
| UV wavelength | 254 nm and 365 nm |
| Transmission UV Wavelength | 302 nm |
| Transmission Area | 200 x 200 mm |
| Working Hours | 4hrs |
| UV lamp power | 8W for 302nm lamp 6W for 254nm and 365nm lamp |
| Dimensions | 425 × 430 × 380mm |
| Net Weight | 20 kg |
| Packing Dimension (Box 1) | 580 × 550 × 550 mm |
| Packing Dimension (Box 2) | 580 × 550 × 550 mm |
| Gross Weight (Box 1) | 12 Kg |
| Gross Weight (Box 2) | 16 Kg |
Specification published by Labozon. Confirm the exact configuration on the written quotation before ordering.
Key features
What the range offers
- Accommodates balance temperature and humidity adjusting system with UV light system for periodic sterilization of chamber
- This unit is specially designed for temperature, Humidity & Light environment
- Built-in audible and visible temperature-limiting alarm system ensures experiments run safely and RS485, RS-484, or RS-232 connector
- Furnished with a humidity sensor to achieve an excellent high humidity environment
- Designed with Microprocessor controller with LCD screen to display for easy monitoring
- Constructed with stainless steel with semicircular arcs at corners for easy cleaning, provide a corrosion-free environment for products
- Built-in air circulating system
- Microprocessor controlled system
Applications
Where it is used
- Salt Spray Test Chamber primarily used for conducting salt mist corrosion test of various accessories and parts, electronic components, coating of metal material and industrial products. The cycling salt mist test chamber can conduct temperature & humidity test, salt mist test, and drying test individually.
- UV Chamber is primarily used for observing and capturing images of nucleic acid electrophoresis gels. It is suitable for DNA and RNA analysis in molecular biology research, genetic studies, and laboratory teaching.
Next step
Tell us the capacity and the duty.
We will confirm the right model, the price and the lead time.